Background: Evaluation of the protein osteopontin (OPN) as a potential new marker in comparison to melanoma inhibitory activity (MIA) for screening and detection of metastatic uveal melanoma. Methods: Plasma levels of 32 patients with uveal melanoma were analyzed for OPN and MIA by enzyme-linked immunosorbent assay (ELISA). Fourteen of these patients had clinically detectable liver metastases. Results: Median plasma concentration of OPN in patients with metastatic disease was 152.01 ng/ml compared to 47.39 ng/ml in patients without clinically detectable metastases (p < 0.001). The difference between the median MIA plasma levels in patients with (13.11 ng/ml) and patients without (5.64 ng/ml) metastatic disease was also statistically significant (p < 0.001). No correlation could be found between MIA or OPN levels and tumor height in patients without clinically detectable metastases. Conclusion: The proteins MIA and OPN seem to be promising tumor markers for the metastasis screening in patients with uveal melanoma.
The serological marker melanoma inhibitory activity (MIA) has been shown to be significantly higher in the serum of patients suffering from metastatic uveal melanoma than in progression-free patients. The objective of this study was to calculate a meaningful receiver operating characteristic (ROC) curve for MIA based on a large patient collective and to find an appropriate threshold value. MIA tumor marker levels of 503 outpatients suffering from uveal melanoma were evaluated using enzyme-linked immunosorbent assay. Fifty-four patients had confirmed metastases and 449 patients showed no overt metastatic disease at the time the blood sample was taken. ROC analysis was performed and the area under the curve (AUC) was calculated. Metastatic patients showed significantly higher MIA levels (median 11.69 ng/ml) than patients in the group without overt metastatic disease (median 6.97 ng/ml) (the Mann-Whitney test, P<0.001). The AUC was 0.84 (95% confidence interval: 0.76-0.91). The ROC resulting from our study can be applied for test comparison by means of AUC. The AUC value of 0.84 for MIA demonstrates the accurate performance of the test. On the basis of this ROC curve, we propose a MIA threshold value for uveal melanoma patients of 8.3 ng/ml (with a corresponding sensitivity of 82% and specificity of 77%, positive predictive value of 0.30 and negative predictive value of 0.97). In patients with higher MIA serum levels, further diagnostics should be initiated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.