The relationship between exposure to violent electronic games and aggressive cognitions and behavior was examined in a longitudinal study. A total of 295 German adolescents completed the measures of violent video game usage, endorsement of aggressive norms, hostile attribution bias, and physical as well as indirect/relational aggression cross-sectionally, and a subsample of N 5 143 was measured again 30 months later. Cross-sectional results at T1 showed a direct relationship between violent game usage and aggressive norms, and an indirect link to hostile attribution bias through aggressive norms. In combination, exposure to game violence, normative beliefs, and hostile attribution bias predicted physical and indirect/relational aggression. Longitudinal analyses using path analysis showed that violence exposure at T1 predicted physical (but not indirect/relational) aggression 30 months later, whereas aggression at T1 was unrelated to later video game use. Exposure to violent games at T1 influenced physical (but not indirect/relational) aggression at T2 via an increase of aggressive norms and hostile attribution bias. The findings are discussed in relation to social-cognitive explanations of long-term effects of media violence on aggression. Aggr. Behav. 35:75-89, 2009.
Objective. To evaluate the validity, responsiveness, and predictive value of power Doppler ultrasonography (PDUS) monitoring of response to tumor necrosis factor (TNF) blocking agents in rheumatoid arthritis (RA).Methods. Three hundred sixty-seven RA patients were prospectively recruited at 25 Spanish centers; complete clinical, laboratory, and PDUS data were obtained on 278 patients. The patients underwent clinical, laboratory, and PDUS assessment at baseline and after 1, 3, 6, and 12 months of anti-TNF treatment, and radiographic assessment of the hands and feet at baseline and 12 months. The Disease Activity Score in 28 joints (DAS28) was recorded at each visit. PDUS examination included 86 intraarticular and periarticular sites in 28 joints. US synovial fluid (SF), synovial hypertrophy (SH), and PD signal were scored in all synovial sites. US count and index for SF, SH, and PD signal were obtained. Sensitivity to change of the PDUS variables was assessed by estimating the smallest detectable difference (SDD) from the intraobserver variability.Results. A significant parallel improvement in DAS28 and PDUS parameters was found at followup assessment (P < 0.0005 for within-subject between-visit changes). The SDD for PDUS parameters was lower than the mean changes throughout followup. Timeintegrated values of US joint count for PD signal and rheumatoid factor (RF) showed predictive value in relation to progression of radiographic erosion (R ؍ 0.64), and time-integrated values of US joint count for PD signal, RF, and erythrocyte sedimentation rate were predictors of progression of the total radiographic score (R ؍ 0.59).Conclusion. These findings indicate that PDUS is a valid method for monitoring response to anti-TNF therapy in RA; results obtained by PDUS are reproducible and sensitive to change. PDUS findings may have predictive value in relation to radiologic outcome.
Our results suggest that US bilateral assessment of one joint, three articular cartilages and two tendons may be valid for diagnosing gout with acceptable sensitivity and specificity.
Objective: To assess the multiexaminer reproducibility and the accuracy comparing with cadaver anatomic specimens of ultrasound (US) measurement of femoral articular cartilage (FAC) thickness. Methods: In 8 flexed cadaver knees, FAC thickness was blindly, independently and consecutively measured twice by 10 rheumatologists at the lateral condyle (LC), medial condyle (MC) and intercondylar notch (IN) with US. After the US measurements, the knees were dissected. Articular cartilage integrity was evaluated macroscopically in the femoral condyles. FAC thickness was blindly measured in the specimens using a stereoscopic magnifying loupe and a digitised image software. Interexaminer and intraexaminer reliability of US FAC thickness measurement and agreement between US and anatomic measurements were assessed by estimating the intraclass correlation coefficient (ICC). Conclusion: US demonstrated a good reproducibility in FAC thickness measurement by multiple examiners. In addition, US FAC thickness measurement was accurate in normal to moderately damaged cartilage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.