Background Bacterial contamination of the intensive care unit (ICU) is one of the risk factors responsible for the high incidence of nosocomial infections that can significantly increase the mortality among ICU patients. Objective The aim of this study was to investigate the bacterial contamination and pathogen isolates from the ICU environment of hospitals in Sana’a city, Yemen. Methods A descriptive cross-sectional study was performed in Sana’a city hospitals from December 5 to December 15, 2019. All hospitals that frequently reported mortality among ICU patients were included. A sterile swab moistened in sterile normal saline was used for sample collection. Seven ICU sites were targeted, including the patient’s bed, bedside table, masks of the oxygen-supplying apparatus, intravenous (IV) stand, door knob, wall, and floor, and two samples from each site were collected. The samples were transported to the National Center of Public Health Laboratory for microbiological culture. Results A total of 112 swabs were collected from the ICUs of eight hospitals. Among these, 87 (77.7%) yielded positive bacterial growth and 109 bacterial strains were isolated, including 62.4% (n=68) gram-positive and 37.6% (n=41) gram-negative bacteria. Coagulase-negative Staphylococcus, Staphylococcus aureus, and Bacillus cereus were the predominant gram-positive bacteria isolated, which accounted for 27.5% (n=30), 21.1% (n=23), and 10.1% (n=11) of all 109 bacterial isolates, respectively. Klebsiella species, Pseudomonas species, and Acinetobacter were the main gram-negative isolates obtained, accounting for 12.8% (n=14), 12.8% (n=14), and 11.9% (n=13) of all 109 bacterial isolates, respectively. The common contaminated sites were the patients’ beds/bedside tables (40/109 strains, 36.7%), floors (24/109 strains, 22.0%), walls (15/109 strains, 13.8%), and masks of the oxygen-supplying apparatus (12/109 strains, 11.0%). The door knobs and IV stands were contaminated by 9 strains, representing 8.3% of the total isolated bacteria. Conclusions The contamination of ICU environments was high and patients’ surroundings were the most contaminated areas. Implementations of strict quality standards of hygienic practices and effective cleaning of inanimate surfaces by the hospitals’ infection control units along with periodic monitoring by the health authority are highly recommended.
BACKGROUND Bacterial contamination of the intensive care unit (ICU) is one of the risk factors responsible for the high incidence of nosocomial infections that can significantly increase the mortality among ICU patients. OBJECTIVE The aim of this study was to investigate the bacterial contamination and pathogen isolates from the ICU environment of hospitals in Sana’a city, Yemen. METHODS A descriptive cross-sectional study was performed in Sana’a city hospitals from December 5 to December 15, 2019. All hospitals that frequently reported mortality among ICU patients were included. A sterile swab moistened in sterile normal saline was used for sample collection. Seven ICU sites were targeted, including the patient’s bed, bedside table, masks of the oxygen-supplying apparatus, intravenous (IV) stand, door knob, wall, and floor, and two samples from each site were collected. The samples were transported to the National Center of Public Health Laboratory for microbiological culture. RESULTS A total of 112 swabs were collected from the ICUs of eight hospitals. Among these, 87 (77.7%) yielded positive bacterial growth and 109 bacterial strains were isolated, including 62.4% (n=68) gram-positive and 37.6% (n=41) gram-negative bacteria. Coagulase-negative <i>Staphylococcus</i>, <i>Staphylococcus aureus</i>, and <i>Bacillus cereus</i> were the predominant gram-positive bacteria isolated, which accounted for 27.5% (n=30), 21.1% (n=23), and 10.1% (n=11) of all 109 bacterial isolates, respectively. <i>Klebsiella</i> species, <i>Pseudomonas</i> species, and <i>Acinetobacter</i> were the main gram-negative isolates obtained, accounting for 12.8% (n=14), 12.8% (n=14), and 11.9% (n=13) of all 109 bacterial isolates, respectively. The common contaminated sites were the patients’ beds/bedside tables (40/109 strains, 36.7%), floors (24/109 strains, 22.0%), walls (15/109 strains, 13.8%), and masks of the oxygen-supplying apparatus (12/109 strains, 11.0%). The door knobs and IV stands were contaminated by 9 strains, representing 8.3% of the total isolated bacteria. CONCLUSIONS The contamination of ICU environments was high and patients’ surroundings were the most contaminated areas. Implementations of strict quality standards of hygienic practices and effective cleaning of inanimate surfaces by the hospitals’ infection control units along with periodic monitoring by the health authority are highly recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.