Differences in blood flow patterns and energy cost between isometric and dynamic resistance exercise may result to variant cardiovascular, neural, and muscle metabolic responses. We aimed to compare the cardiovascular, baroreceptor sensitivity, and muscle oxygenation responses between workload-matched, large muscle-mass isometric and dynamic resistance exercises. Twenty-four young men performed an isometric and a dynamic double leg-press protocol (4 sets×2 min) with similar tension time index (workload). Beat-by-beat hemodynamics, baroreceptor sensitivity, muscle oxygenation, and blood lactate were assessed. The increase in blood pressure was greater (p<0.05) in the 1st set during dynamic than isometric exercise (by ~4.5 mmHg), not different in the 2nd and 3rd sets, and greater in the 4th set during isometric exercise (by ~5 mmHg). Dynamic resistance exercise evoked a greater increase in heart rate, stroke volume, cardiac output, and contractility index (p<0.05), and a greater decline in peripheral resistance, baroreceptor sensitivity, and cardiac function indices than isometric exercise (p<0.05). Participants exhibited a greater reduction in muscle oxyhemoglobin and a greater increase in muscle deoxyhemoglobin in dynamic versus isometric exercise (p<0.001–0.05), with no differences in total hemoglobin and blood lactate. In conclusion, large muscle-mass, multiple-set isometric exercise elicits a relatively similar blood pressure but blunted cardiovascular and baroreceptor sensitivity responses compared to workload-matched dynamic resistance exercise. Differences in blood pressure responses between protocols appear small (~5 mmHg) and are affected by the number of sets. The muscle oxidative stimulus is greater during dynamic resistance exercise than workload-matched isometric exercise.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.