Statement of the problem: Most of the clinical documentation of implant success and survival published in the literature have been issued by either experienced teams from university settings involving strict patient selection criteria or from seasoned private practitioners. By contrast, studies focusing on implants placed and rehabilitated by inexperienced post-graduate students are scarce. Purpose: To record failure rates and identify the contributing factors to implant failure and marginal bone loss (MBL) of implants placed and rehabilitated by inexperienced post-graduate students at the one-year follow-up. Material and Methods: A prospective cohort study was conducted on study participants scheduled for implant therapy at the International University of Catalonia. An experienced mentor determined the treatment plan in accordance with the need of each participant who signed an informed consent. All surgeries and prosthetic rehabilitation were performed by the post-graduate students. Implant failure rate, contributors to implant failure, and MBL were investigated among 24 variables related to patient health, local site, and implant and prosthetic characteristics. The risk of implant failure was analyzed with a simple binary logistic regression model with generalized equation equations (GEE) models, obtaining unadjusted odds ratios (OR). The relationship between MBL and the other independent variables was studied by simple linear regression estimated with GEE models and the Wald chi2 test. Results: One hundred and thirty dental implants have been placed and rehabilitated by post-graduate students. Five implants failed before loading and none after restoration delivery; survival and success rates were 96.15% and 94.62%, respectively. None of the investigated variables significantly affected the implant survival rate. At the one-year follow-up, the mean (SD) MBL was 0.53 (0.39) mm. The following independent variables significantly affected the MBL: Diabetes, implant depth placement. The width of keratinized tissue (KT) and probing depth (PD) above 3 mm were found to be good indicators of MBL, with each additional mm of probing depth resulting in 0.11 mm more MBL. Conclusion: The survival and success rates of dental implants placed and rehabilitated by inexperienced post-graduate students at the one-year follow-up were high. No contributing factor was identified regarding implant failure. However, several factors significantly affected MBL: Diabetes, implant depth placement, PD, and width of KT. Clinical Implications: Survival and success rates of dental implants placed and rehabilitated by inexperienced post-graduate students were high at the one-year follow-up, similar to experienced practitioners. No contributing factors were identified regarding implant failure; however, several factors significantly affected MBL: Diabetes, implant depth placement, PD, and KM.
Objectives: The primary objective of the present study was to find the gold-standard accuracy of voxel-based superimposition of conebeam computed tomography (CBCT) datasets with a protocol developed for the Dolphin Imaging 3D software. The secondary objectives were to analyze reproducibility and efficiency of this protocol. Study Design: Twenty-five CBCT datasets of patients with dental implants present were selected. Each Base Volume dataset was duplicated to create a second volume. Subsequently, both volumes were superimposed with a voxel-based protocol consisting of 3 successive steps ''Side-by-side Superimposition''; ''Overlay Superimposition''; and ''Export Orientation to 2nd Volume''. The protocol's accuracy was evaluated by measuring the mean distance between the apex of each dental implant on the Base Volume and second volume datasets. Efficiency was given by the mean time needed to complete all superimposition steps. Reproducibility was analyzed by calculating the intraclass correlation coefficients. Results: Mean time needed to complete the protocol was 198 seconds. The protocol had a rotational accuracy of 0.108 to 0198 and a translational accuracy of 0.20 to 0.24 mm. Intraobserver and inter-observer reproducibility were 1 and 0.921 to 1, respectively. Conclusions: The protocol is accurate, precise, reproducible, and efficient. The validation of this method enables unbiased analysis of surgical outcomes based on a single, user-friendly software product that is widely available in academic and clinical settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.