PurposeTo assess and compare the incidence of abnormal findings detected during non-contrast-enhanced whole-body magnetic resonance imaging (WB-MRI) in the general population in two age groups: (1) 50 years old and younger; and (2) over 50 years old.Materials and MethodsThe analysis included 666 non-contrast-enhanced WB-MRIs performed on a 1.5-T scanner between December 2009 and June 2013 in a private hospital in 451 patients 50 years old and younger and 215 patients over 50 years old. The following images were obtained: T2-STIR (whole body-coronal plane), T2-STIR (whole spine-sagittal), T2-TSE with fat-saturation (neck and trunk-axial), T2-FLAIR (head-axial), 3D T1-GRE (thorax-coronal, axial), T2-TSE (abdomen-axial), chemical shift (abdomen-axial). Detected abnormalities were classified as: insignificant (type I), potentially significant, requiring medical attention (type II), significant, requiring treatment (type III).ResultsThere were 3375 incidental findings depicted in 659 (98.9%) subjects: 2997 type I lesions (88.8%), 363 type II lesions (10.8%) and 15 type III lesions (0.4%), including malignant or possibly malignant lesions in seven subjects. The most differences in the prevalence of abnormalities on WB-MRI between patients 50 years old and younger and over 50 years old concerned: brain infarction (22.2%, 45.0% respectively), thyroid cysts/nodules (8.7%, 18.8%), pulmonary nodules (5.0%, 16.2%), significant degenerative disease of the spine (23.3%, 44.5%), extra-spinal degenerative disease (22.4%, 61.1%), hepatic steatosis (15.8%, 24.9%), liver cysts/hemangiomas (24%, 34.5%), renal cysts (16.9%, 40.6%), prostate enlargement (5.1% of males, 34.2% of males), uterine fibroids (16.3% of females, 37.9% of females).ConclusionsIncidental findings were detected in almost all of the subjects. WB-MRI demonstrated that the prevalence of the vast majority of abnormalities increases with age.
ObjectiveThe aims of this study were to assess the sensitivity of various magnetic resonance imaging (MRI) sequences for the diagnosis of pulmonary nodules and to estimate the accuracy of MRI for the measurement of lesion size, as compared to computed tomography (CT).MethodsFifty patients with 113 pulmonary nodules diagnosed by CT underwent lung MRI and CT. MRI studies were performed on 1.5T scanner using the following sequences: T2-TSE, T2-SPIR, T2-STIR, T2-HASTE, T1-VIBE, and T1-out-of-phase. CT and MRI data were analyzed independently by two radiologists.ResultsThe overall sensitivity of MRI for the detection of pulmonary nodules was 80.5% and according to nodule size: 57.1% for nodules ≤4mm, 75% for nodules >4-6mm, 87.5% for nodules >6-8mm and 100% for nodules >8mm. MRI sequences yielded following sensitivities: 69% (T1-VIBE), 54.9% (T2-SPIR), 48.7% (T2-TSE), 48.7% (T1-out-of-phase), 45.1% (T2-STIR), 25.7% (T2-HASTE), respectively. There was very strong agreement between the maximum diameter of pulmonary nodules measured by CT and MRI (mean difference -0.02 mm; 95% CI –1.6–1.57 mm; Bland-Altman analysis).ConclusionsMRI yielded high sensitivity for the detection of pulmonary nodules and enabled accurate assessment of their diameter. Therefore it may be considered an alternative to CT for follow-up of some lung lesions. However, due to significant number of false positive diagnoses, it is not ready to replace CT as a tool for lung nodule detection.
ObjectivesTo compare the efficacy of two quantitative methods for discrimination between benign and malignant focal liver lesions (FLLs): apparent diffusion coefficient (ADC) values and T2 relaxation times.MethodsSeventy-three patients with 215 confirmed FLLs (115 benign, 100 malignant) underwent 1.5-T MRI with respiratory-triggered single-shot SE DWI (b = 50, 400, 800) and dual-echo T2TSE (TR = 3,000 ms; TE1 = 84 ms; TE2 = 228 ms). ADC values and T2 relaxation times of FLLs were calculated. Sensitivity, specificity and accuracy of both techniques in diagnosing malignancy were assessed.ResultsThe mean ADC value of malignant tumours (1.07 × 10−3 mm2/s) was significantly lower (P < 0.05) than that of benign lesions (1.86 × 10−3 mm2/s ); however, with the use of the optimal cut-off value of 1.25 × 10−3 mm2/s, 20 false positive (FP) and 20 false negative (FN) diagnoses of malignancy were noted, generating 79 % sensitivity, 82.6 % specificity and 80.9 % accuracy. The mean T2 relaxation time of malignant tumours (64.4 ms) was significantly lower (P < 0.05) than that of benign lesions (476.1 ms). At the threshold of 107 ms 22 FP and 1 FN diagnoses were noted; the sensitivity was 99 %, specificity 80.9 % and accuracy 89.3 %.ConclusionsQuantitative analysis of T2 relaxation times yielded significantly higher sensitivity and accuracy in diagnosing malignant liver tumour than ADC values.Key Points• Diffusion-weighted magnetic resonance imaging is increasingly used for liver lesions.• But ADC values demonstrated only moderate accuracy for differentiation of liver lesions.• T2 relaxation times yielded higher accuracy in diagnosing malignant liver tumours.• Both ADC and T2 values overlapped between focal nodular hyperplasia and malignant lesions.• Nevertheless T2 liver mapping could be valuable for evaluating focal liver lesions.
Polyethylenimine and its pre-synthesized derivatives were conjugated to carbon-encapsulated iron nanoparticles.
A chemical property space defines the adaptability of a molecule to changing conditions and its interaction with other molecular systems determining a pharmacological response. Within a congeneric molecular series (compounds with the same derivatization algorithm and thus the same brute formula) the chemical properties vary in a monotonic manner, i.e., congeneric compounds share the same chemical property space. The chemical property space is a key component in molecular design, where some building blocks are functionalized, i.e., derivatized, and eventually self-assembled in more complex systems, such as enzyme-ligand systems, of which (physico-chemical) properties/bioactivity may be predicted by QSPR/QSAR (quantitative structure-property/activity relationship) studies. The system structure is determined by the binding type (temporal/permanent; electrostatic/covalent) and is reflected in its local electronic (and/or magnetic) properties. Such nano-systems play the role of molecular devices, important in nano-medicine. In the present article, the behavior of polyethylenimine (PEI) macromolecules (linear LPEI and branched BPEI, respectively) with respect to the glucose oxidase enzyme GOx is described in terms of their (interacting) energy, geometry and topology, in an attempt to find the best shape and size of PEIs to be useful for a chosen (nanochemistry) purpose.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.