Background: Brachial plexopathy (BP) is a potentially serious complication from stereotactic body radiation therapy (SBRT) that has not been widely studied. Therefore, we compared datasets from two different institutions and generated a brachial plexus dose-response model, to quantify what dose constraints would be needed to minimize the effect on normal tissue while still enabling potent therapy for the tumor.Methods: Two published SBRT datasets were pooled and modeled from patients at Indiana University and the Richard L. Roudebush Veterans Administration Medical Center from 1998 to 2007, as well as the Karolinska Institute from 2008 to 2013. All patients in both studies were treated with SBRT for apically located lung tumors localized superior to the aortic arch. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE) and a probit dose response model was created with maximum likelihood parameter fitting.Results: This analysis includes a total of 89 brachial plexus Dmax values from both institutions. Among the 14 patients who developed BP, the most common complications were grade 2, comprising 7 patients. The median follow-up was 30 months (range 6.1-72.2) in the Karolinska dataset, and Indiana had a median of 13 months (range 1-71). Both studies had a median range of 3 fractions, but in the Indiana dataset 9 patients were treated in 4 fractions and the paper did not differentiate which ones were which, so our analysis is considered to be in 3-4 fractions, which is one of the main limitations. The probit model showed that the risk of BP with Dmax of 26 Gy in 3-4 fractions is 10%, and 50% with Dmax of 70 Gy in 3 -4 fractions.Conclusions: This analysis is only a preliminary result because more details are needed, and more comprehensive datasets are needed from a much broader cross-section of clinical practices. When more institutions join the QUANTEC and HyTEC methodology of reporting sufficient details to enable data pooling, our field will finally reach an improved understanding of human dose tolerance.
Background: Brachial plexopathy (BP) is a potentially serious complication from stereotactic body radiation therapy (SBRT) that has not been widely studied. Therefore, we compared datasets from two different institutions and generated a brachial plexus dose-response model, to quantify what dose constraints would be needed to minimize the effect on normal tissue while still enabling potent therapy for the tumor.Methods: Two published SBRT datasets were pooled and modeled from patients treated with SBRT at Indiana University and the Richard Roudebush VAMC from 1998 to 2007, as well as the Karolinska Institute from 2008 to 2013. All patients in both studies were treated with SBRT for apically located lung tumors localized superior to the aortic arch. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE) and a probit dose response model was created with maximum likelihood parameter fitting.Results: This analysis includes a total of 89 brachial plexus Dmax values from both institutions. Among the 14 patients who developed BP, the most common complications were grade 2, comprising 7 patients. The median follow-up was 30 months (range 6.1-72.2) in the Karolinska dataset, and Indiana had a median of 13 months (range 1-71). Both studies had a median range of 3 fractions, but in the Indiana dataset 9 patients were treated in 4 fractions and the paper did not differentiate which ones were which, so our analysis is considered to be in 3-4 fractions, which is one of the main limitations. The probit model showed that the risk of BP with Dmax of 26 Gy in 3-4 fractions is 10%, and 50% with Dmax of 70 Gy in 3 -4 fractions.Conclusions: This analysis is only a preliminary result because more details are needed, and more comprehensive datasets are needed from a much broader cross-section of clinical practices. When more institutions join the QUANTEC and HyTEC methodology of reporting sufficient details to enable data pooling, our field will finally reach an improved understanding of human dose tolerance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.