ANG II interacts with the sympathetic nervous system at central nervous blood pressure-regulating structures, including the baroreflex. It is unknown whether prolonged BP elevation mediated by high ANG II plasma levels could induce a persistent shift of the central nervous baroreflex setpoint, lasting beyond the short ANG II plasmatic half time of a few seconds, thereby consolidating elevated BP and/or increased SNA in healthy humans. In a blinded crossover design, ANG II or placebo (saline) was infused for a 6-h period in 12 resting normotensive students (6 males, 6 females) raising BP to borderline hypertensive levels. Between 60 and 120 min after the infusion period, muscle sympathetic nerve activity (MSNA) was assessed microneurographically and correlated with oscillometric BP measurements and heart rate at supine rest (baseline) and during pharmacologic baroreceptor challenge. Infusion of ANG II increased BP to borderline-hypertensive levels, as intended, whereas heart rate remained unaltered. At baroreflex assessment (i.e., 60-120 min after end of infusion period), systolic BP was significantly higher compared with placebo (Δ8.4 ± 3.1 mmHg; P < 0.05), whereas diastolic values were nearly equal between conditions. Baseline MSNA was neither decreased nor increased, and baroreflex sensitivity to vasoactive drug challenge was not altered. Our results show that elevation of ANG II plasma levels over 6 h was able to increase systolic, but not diastolic, BP far beyond blood-mediated ANG II effects. MSNA or heart rate did not counter-regulate this BP elevation, indicating that ANG II had sustainably reset the central nervous BP threshold of sympathetic baroreflex function to accept elevated BP input signals without counter-regulatory response.
AIMTo evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODSRetrospectively we identified 89 consecutive patients (41 female, mean age 49 ± 18 years) who had X-ray (CR) and computed tomography (CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex (PQC) was measured using lateral views (CR) and sagittal reconstructions (CT). Pearson’s test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign (PQS) was defined as a PQC > 8.0 mm (female) or > 9.0 mm (male). Frykman classification was utilized to assess the severity of fractures.RESULTSForty-four/89 patients (49%) had a distal radius fracture (Frykman I n = 3, II n = 0, III n = 10, IV n = 5, V n = 2, VI n = 2, VII n = 9, VIII n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views (CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions (CT), resulting in a significant correlation coefficient of 0.795. A positive PQS at CR was present in 21/44 patients (48%) with distal radius fracture and in 2/45 patients (4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSIONA positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.