This work reports the use of iron tetrapyridinoporphyrazine (FeTPyPz) as a highly selective catalyst in the construction of an electrochemical sensor for estradiol valerate (EV) determination. The sensor was prepared by modifying a carbon paste with FeTPyPz. The best results were obtained in a mixture of acetonitrile (MeCN) and 0.1 mol L(-1) phosphate buffer solution (pH 6.0) in a volume ratio of 47 : 53. A linear response range was observed between 45 and 450 micromol L(-1) with a sensitivity of 12160 +/- 306 microA L mol(-1) and quantification and detection limits of 45 and 13 micromol L(-1), respectively. The repeatability, expressed as the relative standard deviation (RSD) for n = 10, was 5.9% ([EV] = 50 micromol L(-1)). The reproducibility (RSD) for the sensor construction was better than 4% and the operational stability (RSD) over 50 measurements was 1.8%. A detailed investigation regarding the selectivity and electrochemical characteristics was carried out. Finally, in a first step to evaluate the application potential of the sensor, it was successfully applied to determine EV in a commercial formulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.