Extracorporeal shock wave therapy is a treatment of choice in patients with musculoskeletal disorders. The aim of this study was to investigate the effect of radial shock wave therapy (RSWT) on muscle spasticity of plantar flexor muscles in children with cerebral palsy. This was an open, controlled, observational study with one placebo treatment session, followed 4 weeks later by one active treatment session. Procedures and measurements were performed on inpatients of the Physical and Rehabilitation department of the Medical University Hospital, Plovdiv, Bulgaria. Twenty-five children, mean age 4.84±3.11 years, with spastic diplegia and hemiplegia participated in the study. They received a single session of RSWT to the plantar flexors of the foot. The following clinical methods were used for outcome assessment before, after, and 2 and 4 weeks later: passive range of motion, Modified Ashworth Scale. Baropodometric measurements were performed before and after the placebo and active session. After placebo application, no changes measured by clinical or instrumental methods were found. After RSWT, a significant increase in passive range of motion was observed: 47.00±2.29° versus 33.25±2.20° (P<0.001), which persisted at the second (46.87±2.08°, P<0.001) and fourth week (44.12±1.93°, P<0.001) after treatment. The Modified Ashworth Scale score decreased from 2.77 to 2.00 points (P<0.001), which persisted at the second (mean 2.05±0.07 points, P<0.001) and fourth week (2.15±0.76 points, P<0.001) after treatment. Baropodometric measurement showed a significant increase in the contact plantar surface area of the affected foot (from 81.32±6.14 to 101.58±5.41 cm, P<0.001) and in heel pressure (from 50.47±6.61 to 75.17±3.42 N/cm, P<0.001). There is a significant reduction in the spasticity of plantar flexor muscles in children with cerebral palsy after a single session of RSWT and this improvement remains at the 4-week follow-up.
The proposed study presents an original concept for the design of a walking robot with a minimum number of motors. The robot has a simple design and control system, successfully moves by walking, avoids or overcomes obstacles using only two independently controlled motors. Described are basic geometric and kinematic dependencies related to its movement. It is proposed optimization of basic dimensions of the robot in order to reduce energy losses when moving on flat terrain. Developed and produced is a 3-D printed prototype of the robot. Simulation and experiments for overcoming an obstacle are presented. Trajectories and instantaneous velocities centers of links from the robot are experimentally determined. The phases of walking and the stages of overcoming an obstacle are described. The theoretical and experimental results are compared. The suggested dimensional optimization approaches to reduce energy loss and experimental determination of the instant center of rotation are also applicable to other walking robots.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.