The processes of three-dimensional optical scanning depend on the reflection of the surface to be digitized. To scan specular or translucent surfaces, it is necessary to apply a coating material which interferes with the accuracy of the three-dimensional measurements. This study proposes the use of gold, silver, platinum, and carbon by sputtering to coat the surfaces to be scanned. The effects of these materials on the accuracy of the three-dimensional scanning were evaluated and compared with those of two frequently used materials, namely, talc and non-aqueous wet developer for penetrant testing. To verify the resulting geometric variations, specimens were scanned before and after the application of each coating material. The results showed that the intrinsic errors of the three-dimensional scanning process, such as the registration of several point clouds, can have more significant effects than the coating material used. Measurements taken from a single point cloud showed dimensional tolerances of approximately 0.01 mm for gold, platinum, and carbon coating. These coatings offer significantly higher accuracy than the traditionally used developer and are suggested for accurate three-dimensional scanning of specular and translucent surfaces.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.