PurposeTo optimise the intravoxel incoherent motion (IVIM) imaging of the liver on a 3.0T scanner by assessing parameter reproducibility on free-breathing (FB) and respiratory-triggered (RT) sequences acquired with different numbers of signal averages (NSA).Material and methodsIn this prospective study 20 subjects (M/F: 10/10; age: 25-62 years, mean: 39 years) underwent IVIM magnetic resonance imaging (MRI) on a 3.0T scanner using an 18-channel phase-arrayed coil and four different echo-planar sequences, each with 10 b values: 0, 10, 30, 50, 75, 100, 150, 200, 500, and 900 s/mm2. Images were acquired with FB and RT with NSA = 1-4 (FBNSA1-4, RTNSA1-4) and with NSA = 3-6 (FBNSA3-6, RTNSA3-6). Subsequently, for the assessment of reproducibility of IVIM-derived parameters (f, D, D*), each subject was scanned again with an identical protocol during the same session. IVIM parameters were calculated. The distribution of IVIM-parameters for each DWI sequence were given as the median value with first and third quartile. Inter-scan reproducibility for each IVIM parameter was evaluated using coefficient of variance and Bland-Altman difference. Differences between FB sequence and RT sequence were tested using non-parametric Wilcoxon signed-rank test.ResultsMean coefficient of variance (%) for f, D, and D* ranged from 60 to 64, from 58 to 84, and from 82 to 99 for FBNSA1-4 sequence; from 50 to 69, from 41 to 97, and from 80 to 82 for RTNSA1-4 sequence; from 22 to 27, 15, and from 70 to 80 for FBNSA3-6 sequence; and from 21 to 32, from 12 to, and from 50 to 80 for RTNSA3-6 sequence, respectively.ConclusionsIncreasing the number of signal averages for IVIM acquisitions allows us to improve the reproducibility of IVIM-derived parameters. The sequence acquired during free-breathing with NSA = 3-6 was optimal in terms of reproducibility and acquisition time.
SummaryBackgroundRegular quality control is required in Poland only for those methods of medical imaging which involve the use of ionizing radiation but not for ultrasonography. It is known that the quality of ultrasound images may be affected by the wearing down or malfunctioning of equipment.Material/MethodsAn evaluation of image quality was carried out for 22 ultrasound scanners equipped with 46 transducers. The CIRS Phantom model 040GSE was used. A set of tests was established which could be carried out with the phantom, including: depth of penetration, dead zone, distance measurement accuracy, resolution, uniformity, and visibility of structures.ResultsWhile the dead zone was 0 mm for 89% of transducers, it was 3 mm for the oldest transducer. The distances measured agreed with the actual distances by 1 mm or less in most cases, with the largest difference of 2.6 mm. The resolution in the axial direction for linear transducers did not exceed 1 mm, but it reached even 5 mm for some of the convex and sector transducers, especially at higher depths and in the lateral direction. For 29% of transducers, some distortions of anechoic structures were observed. Artifacts were detected for several transducers.ConclusionsThe results will serve as a baseline for future testing. Several cases of suboptimal image quality were identified along with differences in performance between similar transducers. The results could be used to decide on the applicability of a given scanner or transducer for a particular kind of examination.
Introduction. In order to improve the efficacy of intravoxel incoherent motion (IVIM) parameters in characterising specific tissues, a new concept is introduced: the perfusion–diffusion ratio (PDR), which expresses the relationship between the signal S b decline rate as a result of IVIM and the rate of signal S b decline due to diffusion. The aim of this study was to investigate this novel approach in the differentiation of solid primary liver lesions. Material and Methods. Eighty-three patients referred for liver MRI between August 2017 and January 2020 with a suspected liver tumour were prospectively examined with the standard liver MRI protocol extended by DWI-IVIM sequence. Patients with no liver lesions, haemangiomas, or metastases were excluded. The final study population consisted of 34 patients with primary solid liver masses, 9 with FNH, 4 with regenerative nodules, 10 with HCC, and 11 with CCC. The PDR coefficient was introduced, defined as the ratio of the rate of signal S b decrease due to the IVIM effect to the rate of signal S b decrease due to the diffusion process, for b = 0 . Results. No significant differences were found between benign and malignant lesions in the case of IVIM parameters ( f , D , or D ∗ ) and ADC. Significant differences were observed only for PDR, with lower values for malignant lesions ( p = 0.03 ). The ROC analysis yielded an AUC value for PDR equal to 0.74, with a cut-off value of 5.06, sensitivity of 81%, specificity of 77%, and accuracy of 79%. Conclusion. PDR proved to be more effective than IVIM parameters and ADC in the differentiation of solid benign and malignant primary liver lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.