Access to high quality acute trauma care is well established across parts of Canada but a clear urban/rural divide persists. Regional efforts to improve short- and long-term outcomes after severe trauma should focus on the optimization of access to pre-hospital care and acute trauma care in rural communities using locally relevant strategies or novel care delivery options.
Summary Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79). Interpretation In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. Funding National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
Background: Observational studies have suggested that accelerated surgery is associated with improved outcomes in patients with a hip fracture. The HIP ATTACK trial assessed whether accelerated surgery could reduce mortality and major complications. Methods:We randomised 2970 patients from 69 hospitals in 17 countries. Patients with a hip fracture that required surgery and were ≥45 years of age were eligible. Patients were randomly assigned to accelerated surgery (goal of surgery within 6 hours of diagnosis; 1487 patients) or standard care (1483 patients). The co-primary outcomes were 1.) mortality, and 2.) a composite of major complications (i.e., mortality and non-fatal myocardial infarction, stroke, venous thromboembolism, sepsis, pneumonia, life-threatening bleeding, and major bleeding) at 90 days after randomisation. Outcome adjudicators were masked to treatment allocation, and patients were analysed according to the intention-to-treat principle; ClinicalTrials.gov, NCT02027896. Findings:The median time from hip fracture diagnosis to surgery was 6 hours (interquartile range [IQR] 4-9) in the accelerated-surgery group and 24 hours (IQR 10-42) in the standard-care group, p<0.0001. Death occurred in 140 patients (9%) assigned to accelerated surgery and 154 patients (10%) assigned to standard care; hazard ratio (HR) 0.91, 95% CI 0.72-1.14; absolute risk reduction (ARR) 1%, 95% CI -1-3%; p=0.40. The primary composite outcome occurred in 321 patients (22%) randomised to accelerated surgery and 331 patients (22%) randomised to standard care; HR 0.97, 95% CI 0.83-1.13; ARR 1%, 95% CI -2-3%; p=0.71.Interpretation: Among patients with a hip fracture, accelerated surgery did not significantly lower the risk of mortality or a composite of major complications compared to standard care.
Background: The incidence of injuries from cast saws during cast removal ranges from 0.12% to 4.3%. With 1 second or less of exposure time, a temperature of 65°C can cause partial thickness burns. Despite numerous studies that recommend avoiding the use of a dull blade, there is no objective measure of what defines dullness. Methods: Plaster and fiberglass casts were collected and measured after removal from patients in the clinic. A series of slabs were constructed based on these measurements. To simulate our emergency department setting, a Stryker 940 cast saw without an attached vacuum was used to split plaster slabs. A thermocouple was used to directly measure the 940-23 ion-nitride saw blade temperature after each use. To simulate our orthopaedic clinic setting, a Stryker 940 cast saw with an attached vacuum was used to split fiberglass and plaster slabs. Three blades were tested in each setting, bivalving 50 slabs each. Results: For the plaster slabs split without a vacuum, average blade temperature of the 3 blades reached 65°C on the 42nd cast. However, the individual blades exceeded 65°C on the 33rd, 31st, and 38th casts, respectively. For the fiberglass and plaster slabs split with a vacuum, average blade temperature reached a maximum of 57.5°C in the first 50 trials. Extrapolating from this data, the blade is predicted to exceed 65°C on the 104th cast. Conclusions: When a Stryker 940 cast saw without vacuum is used to cut plaster casts, the ion-nitride blade should be changed frequently, at minimum after 60 casts have been split, or 30 casts have been bivalved. When a Stryker 940 cast saw with vacuum is used to remove fiberglass and plaster casts, the ion-nitride blade should be changed after removing 103 casts. A cast saw with an attached vacuum should be used whenever possible to minimize the risk of burning patients. Clinical Relevance: Determine how often a cast saw blade should be changed to minimize risk of burning patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.