Thermal neutrons are found in reactor, radiotherapy, aircraft, and space environments. The purpose of this study was to characterise the dosimetry and microdosimetry of thermal neutron exposures, using three simulation codes, as a precursor to quantitative radiobiological studies using blood samples. An irradiation line was designed employing a pyrolytic graphite crystal or-alternatively-a super mirror to expose blood samples to thermal neutrons from the National Research Universal reactor to determine radiobiological parameters. The crystal was used when assessing the relative biological effectiveness for dicentric chromosome aberrations, and other biomarkers, in lymphocytes over a low absorbed dose range of 1.2-14 mGy. Higher exposures using a super mirror will allow the additional quantification of mitochondrial responses. The physical size of the thermal neutron fields and their respective wavelength distribution was determined using the McStas Monte Carlo code. Spinning the blood samples produced a spatially uniform absorbed dose as determined from Monte Carlo N-Particle version 6 simulations. The major part (71%) of the total absorbed dose to blood was determined to be from the N(n,p)C reaction and the remainder from the H(n,γ)H reaction. Previous radiobiological experiments at Canadian Nuclear Laboratories involving thermal neutron irradiation of blood yielded a relative biological effectiveness of 26 ± 7. Using the Particle and Heavy Ion Transport Code System, a similar value of ∼19 for the quality factor of thermal neutrons initiating the N(n,p)C reaction in soft tissue was determined by microdosimetric simulations. This calculated quality factor is of similar high value to the experimentally-derived relative biological effectiveness, and indicates the potential of thermal neutrons to induce deleterious health effects in superficial organs such as cataracts of the eye lens.
A total of 497 smelter employees from New Brunswick participated in a bone lead survey conducted by McMaster University in 2008 to examine the efficiency of lead exposure control programmes and a four-element 'clover-leaf' geometry detector system. Nearly 42% of the subjects had participated in both the previous surveys performed in 1994 and 1999. After developing the clover-leaf geometry system in 2006, the reliability of the system based on examining the consistency of four detectors and improving the minimum detection limit (MDL) was tested for the first time in 2008 by measuring lead levels of a large population that was occupationally exposed to lead. The Z test was used to study the distribution of the lead concentration calculated based on K(α) and K(β) lead x-rays, where the results were broadly consistent with a normal distribution criterion, with relatively small means and standard deviations of between 1 and 2. The MDL of the clover-leaf geometry system was improved on average for tibia and calcaneus by a factor of 3.1 compared to the 1999 and 1994 surveys in which a conventional system (one detector) was used. Furthermore, by comparing the results of the three mentioned surveys, the 2008 results were found to represent the highest precision.
The design, simulation results and measurements of a new neutron energy spectrometer are presented. The device, which may be called NNS, for Nested Neutron Spectrometer, works under the same principles as a Bonner Sphere Spectrometer (BSS) System, i.e. whereby a thermal neutron detector is surrounded by a polyethylene moderator. However, the moderator is cylindrical in shape. The different thicknesses of moderator are created by inserting one cylinder into another, much like nested Russian dolls. This design results in a much lighter instrument that is also easier to use in the field. Simulations and measurements show that, despite its shape, the device can be made to offer a near angular isotropic response to neutrons and that unfolded neutron spectra are in agreement with those obtained with a more traditional BSS.
Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.