Precise diagnostics of picocoulomb level particle bunches produced by laser plasma accelerators (LPAs) can be a significant challenge. Without proper care, the small signals associated with such bunches can be dominated by a background generated by laser, target, laser-plasma interaction and particle induced radiation. In this paper, we report on first charge measurements using the newly developed Turbo-ICT for LPAs. We outline the Turbo-
a b s t r a c tTwo types of neutron monitors with fine spatial resolutions are proposed based on vibrating wires. In the first type, neutrons interact with a vibrating wire, heat it, and lead to the change of its natural frequency, which can be precisely measured. To increase the heat deposition during the neutron scattering, the use of gadolinium layer that has the highest thermal neutron capture cross-section among all elements is proposed. The second type uses the vibrating wire as a "resonant target." Besides the measurement of beam profile according to the average signal, the differential signal synchronized with the wire oscillations defines the beam profile gradient. The monitor's spatial resolution is defined by the wire's diameter.
At the LEP e+/e-collider at CERN, Geneva, a Spectrometer is used to determine the beam energy with a relative accuracy of 10-4. The Spectrometer measures the change in bending angle in a well-characterised dipole magnet as LEP is ramped. The beam trajectory is obtained using three beam position monitors (BPMs) on each side of the magnet. The error on each BPM measurement should not exceed 1 micron if the desired accuracy on the bending angle is to be reached. The BPMs used consist of an aluminium block with an elliptical aperture and four capacitive button pickup electrodes. The button signals are fed to customised electronics supplied by Bergoz. The electronics use time multiplexing of individual button signals through a single processing chain to optimise for longterm stability. We report on our experience of the performance of these electronics, describing measurements made with test signals and with beam. We have implemented a beam-based calibration procedure and have monitored the reproducibility of the measurements obtained over time. Measurements show that a relative accuracy better than 300 nm is achievable over a period of 1 hr.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.