The aim of this study was to assess the posterior stability of two different designs of total knee replacement (TKR) with deep-dished mobile bearing (MB) implants using stress X-rays. In a prospective non-randomized consecutive study, 34 patients with primary osteoarthritis of the knee underwent TKR. In group A (17 knees), they received a MB insert with a Duracon prosthesis and in group B (18 knees), a Genesis prosthesis. In all cases the posterior cruciate ligament (PCL) was resected. All patients had pre- and post-operative kneeling X-rays and were clinically evaluated with the Knee Society Score. Measurements on the radiographs were taken by tracing a line along the posterior cortex of the tibia and then measuring the perpendicular distance to a point marked at the posterior corner of Blumensaat's line. The average follow up was 10.7 months for group A and 5.4 months for group B. No statistical difference could be found in terms of clinical results and pre- and post-operative kneeling X-rays between the two groups. In each group, all knees demonstrated a significant posterior tibial translation postoperatively compare to their pre-operative status (p<0.0001). There are advantages in resecting the PCL in TKR: mobile flexion gap, correction of fixed deformity, more flexibility to adjust the joint line. The use of a deep dished polyethylene (PE) insert provides stability and use of MB insert reduces PE wear whilst retaining congruity. Two designs of deep-dished MB inserts showed significant posterior tibial translation on stress X-rays. It remains to be determined what amount of laxity is optimal for clinical function and polyethylene longevity.
The deep-dished fixed-bearing TKR as well as the deep-dished rotating mobile-bearing TKR demonstrated significant posterior tibial translation on kneeling stress X-ray. It remains to be determined what amount of joint play is optimal for clinical function and to minimise shear forces and PE wear. Moreover the amount of posterior tibial translation was significantly higher with the mobile-bearing insert, which could be directly related to the asymmetric rotational mobility of the tibial insert. A long-term follow-up is necessary to investigate whether our findings correlate with the survival-rate of these specific implants.
This study has shown that the opening of individually wrapped items increases the risk for potential contamination of an operative field, suggesting that the move towards using individually wrapped components for surgery warrants further investigation. We believe that orthopaedic operating theatres should consider the use of screw banks to minimize the risk of contamination.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.