This paper describes a procedure that makes it possible to design and fabricate (including sealing) microfluidic systems in an elastomeric material [Formula: see text] poly(dimethylsiloxane) (PDMS) [Formula: see text] in less than 24 h. A network of microfluidic channels (with width >20 μm) is designed in a CAD program. This design is converted into a transparency by a high-resolution printer; this transparency is used as a mask in photolithography to create a master in positive relief photoresist. PDMS cast against the master yields a polymeric replica containing a network of channels. The surface of this replica, and that of a flat slab of PDMS, are oxidized in an oxygen plasma. These oxidized surfaces seal tightly and irreversibly when brought into conformal contact. Oxidized PDMS also seals irreversibly to other materials used in microfluidic systems, such as glass, silicon, silicon oxide, and oxidized polystyrene; a number of substrates for devices are, therefore, practical options. Oxidation of the PDMS has the additional advantage that it yields channels whose walls are negatively charged when in contact with neutral and basic aqueous solutions; these channels support electroosmotic pumping and can be filled easily with liquids with high surface energies (especially water). The performance of microfluidic systems prepared using this rapid prototyping technique has been evaluated by fabricating a miniaturized capillary electrophoresis system. Amino acids, charge ladders of positively and negatively charged proteins, and DNA fragments were separated in aqueous solutions with this system with resolution comparable to that obtained using fused silica capillaries.
This Account summarizes techniques for fabrication and applications in biomedicine of microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The methods and applications described focus on the exploitation of the physical and chemical properties of PDMS in the fabrication or actuation of the devices. Fabrication of channels in PDMS is simple, and it can be used to incorporate other materials and structures through encapsulation or sealing (both reversible and irreversible).
Microfluidic devices are finding increasing application as analytical systems, biomedical devices, tools for chemistry and biochemistry, and systems for fundamental research. Conventional methods of fabricating microfluidic devices have centered on etching in glass and silicon. Fabrication of microfluidic devices in poly(dimethylsiloxane) (PDMS) by soft lithography provides faster, less expensive routes than these conventional methods to devices that handle aqueous solutions. These soft‐lithographic methods are based on rapid prototyping and replica molding and are more accessible to chemists and biologists working under benchtop conditions than are the microelectronics‐derived methods because, in soft lithography, devices do not need to be fabricated in a cleanroom. This paper describes devices fabricated in PDMS for separations, patterning of biological and nonbiological material, and components for integrated systems.
This paper describes a procedure for making topologically complex three-dimensional microfluidic channel systems in poly(dimethylsiloxane) (PDMS). This procedure is called the "membrane sandwich" method to suggest the structure of the final system: a thin membrane having channel structures molded on each face (and with connections between the faces) sandwiched between two thicker, flat slabs that provide structural support. Two "masters" are fabricated by rapid prototyping using two-level photolithography and replica molding. They are aligned face to face, under pressure, with PDMS prepolymer between them. The PDMS is cured thermally. The masters have complementary alignment tracks, so registration is straightforward. The resulting, thin PDMS membrane can be transferred and sealed to another membrane or slab of PDMS by a sequence of steps in which the two masters are removed one at a time; these steps take place without distortion of the features. This method can fabricate a membrane containing a channel that crosses over and under itself, but does not intersect itself and, therefore, can be fabricated in the form of any knot. It follows that this method can generate topologically complex microfluidic systems; this capability is demonstrated by the fabrication of a "basketweave" structure. By filling the channels and removing the membrane, complex microstructures can be made. Stacking and sealing more than one membrane allows even more complicated geometries than are possible in one membrane. A square coiled channel that surrounds, but does not connect to, a straight channel illustrates this type of complexity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.