Compared with a lightwand which is used blind, Optiscope , a rigid video-stylet, can provide direct imaging of airway structures, potentially offering improved conditions in cervical spine-immobilised patients. We randomly assigned 168 patients who required cervical immobilisation during tracheal intubation to use of the Optiscope or the lightwand. The initial intubation success rate (95% CI) was 90 (82-95)% with the Optiscope and 87 (78-93)% with the lightwand (p = 0.626). Median (IQR [range]) intubation time was longer (19 (12-41 [5-195] s vs. 15 (8-29 [3-117] s; p = 0.016), and there were fewer scooping movements (1 (1-2 [0-9]) vs. 2 (1-3 [0-14]); p = 0.002) when using the Optiscope compared with the lightwand. The incidence of postoperative airway complications was similar in the two groups. The devices were equivalent with respect to initial intubation success rate but the Optiscope yielded slightly longer intubating times.
Limited evidence is available in the literature regarding the fate of the unfused structural thoracic curve following selective thoracolumbar-lumbar curve fusion (SLF) in Lenke 6C adolescent idiopathic scoliosis (AIS) patients. Therefore, we compared the outcomes of SLF between Lenke 6C and 5C AIS patients. We retrospectively reviewed 31 patients Lenke 5C (n = 18) and Lenke 6C (n = 13) AIS patients who underwent SLF at a single institution. Multiple radiological parameters were measured using whole-spine radiographs taken before and after surgery and at the last follow-up visit. SRS-22 at the final follow-up was obtained for clinical assessment. A total of 31 patients with a mean age of 14.6 years at operation who were followed for a mean of 6.4 years were included in this study. The Cobb angle of the unfused thoracic curve was spontaneously corrected immediately following SLF and increased slightly but not significantly at the final follow-up in both groups (Lenke 5C: pre 33.0°, post 14.4°, final 19.4°, Lenke 6C: pre 46.1°, post 31.7°, final 34.2°). At every time point, the thoracic Cobb angle was significantly larger in the Lenke 6C. SRS-22 score at the final follow-up, including the self-image domain, did not differ between the two groups. In this study, SLF for Lenke 6C AIS achieved a significant spontaneous correction of the unfused thoracic curve and yielded a comparable SRS-22 result at the final follow-up to that of Lenke 5C. Our findings suggest that SLF is a viable treatment option for Lenke 6C AIS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.