Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometHc parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the A and ~ values for the initial surface. It is shown that larger changes can also be measured and that the values of A and ~ for the initial surface need not be known beforehand. To illustrate the method measurements are made relating to the anodising of a hanging mercury drop electrode in 1 mol dm -3 NaOH; under these conditions a thick oxide layer is known to be formed.(1) INTRODUCTION Ellipsometry is a widely used technique for in situ studies of film formation and growth on mirror-like substrates. Manual-nulling ellipsometry, however, is much too slow to permit a kinetic study of dynamic surface processes. Different types of automatic ellipsometers have been built to overcome this problem [ 1,2]. Various efforts have also been made to obtain transient measurements with simple instrumentation in the form of intensity-monitoring techniques.In the first attempts [3--5] light intensity changes were recorded by means of an ellipsometer whose components were adjusted to an extinction-setting under film-free conditions. Later [6--8] sensitivity was increased by recording transients with off-null settings of the ellipsometer components. Quantitative methods of measurement were also described [9--11].Horkans et al. [12,13] and Barrett and Parsons [14] realized that the reflectivity of the surface also contributes to the intensity expression; this factor was not taken into account in the earlier treatments.Horkans et al. [12,13] derived an expression of the formwhere I is the measured intensity, R is the reflectivity of the surface and A and are the ellipsometric parameters, a and fl_are co_mplex functions of A, 4, A and P. a and ~ can be calculated once the A and ~ of the unperturbed surface are known. Thus, if three separate measurements are performed with the same polarizer setting P and three different analyser settings A, a system of three equa-
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.