Objectives: Cochlear implants (CIs) have been shown to benefit patients with single-sided deafness (SSD) in terms of tinnitus reduction, localization, speech understanding, and quality of life (QoL). While previous studies have shown cochlear implantation may benefit SSD patients, it is unclear which point of comparison is most relevant: baseline performance before implantation versus performance with normal-hearing (NH) ear after implantation. In this study, CI outcomes were assessed in SSD patients before and up to 6 mo postactivation. Benefits of cochlear implantation were assessed relative to binaural performance before implantation or relative to performance with the NH ear alone after implantation. Design: Here, we report data for 10 patients who completed a longitudinal, prospective, Food and Drug Administration–approved study of cochlear implantation for SSD patients. All subjects had severe to profound unilateral hearing loss in one ear and normal hearing in the other ear. All patients were implanted with the MED-EL CONCERTO Flex 28 device. Speech understanding in quiet and in noise, localization, and tinnitus severity (with the CI on or off) were measured before implantation (baseline) and at 1, 3, 6 mo postactivation of the CI processor. Performance was measured with both ears (binaural), the CI ear alone, and the NH ear alone (the CI ear was plugged and muffed). Tinnitus severity, dizziness severity, and QoL were measured using questionnaires administered before implantation and 6 mo postactivation. Results: Significant CI benefits were observed for tinnitus severity, localization, speech understanding, and QoL. The degree and time course of CI benefit depended on the outcome measure and the reference point. Relative to binaural baseline performance, significant and immediate (1 mo postactivation) CI benefits were observed for tinnitus severity and speech performance in noise, but localization did not significantly improve until 6 mo postactivation; questionnaire data showed significant improvement in QoL 6 mo postactivation. Relative to NH-only performance after implantation, significant and immediate benefits were observed for tinnitus severity and localization; binaural speech understanding in noise did not significantly improve during the 6-mo study period, due to variability in NH-only performance. There were no correlations between behavioral and questionnaire data, except between tinnitus visual analog scale scores at 6 mo postactivation and Tinnitus Functional Index scores at 6 mo postactivation. Conclusions: The present behavioral and subjective data suggest that SSD patients greatly benefit from cochlear implantation. However, to fully understand the degree and time course of CI benefit, the outcome measure and point of comparison should be considered. From a clinical perspective, binaural baseline performance is a relevant point of comparison. The lack of correlation between behavioral and questionnaire data suggest that represent independent measures of CI benefit for SSD patients.
There are three main cues to sound location: the interaural differences in time (ITD) and level (ILD) as well as the monaural spectral shape cues. These cues are generated by the spatial- and frequency-dependent filtering of propagating sound waves by the head and external ears. Although the chinchilla has been used for decades to study the anatomy, physiology, and psychophysics of audition, including binaural and spatial hearing, little is actually known about the sound pressure transformations by the head and pinnae and the resulting sound localization cues available to them. Here, we measured the directional transfer functions (DTFs), the directional components of the head-related transfer functions, for 9 adult chinchillas. The resulting localization cues were computed from the DTFs. In the frontal hemisphere, spectral notch cues were present for frequencies from ~6–18 kHz. In general, the frequency corresponding to the notch increased with increases in source elevation as well as in azimuth towards the ipsilateral ear. The ILDs demonstrated a strong correlation with source azimuth and frequency. The maximum ILDs were < 10 dB for frequencies < 5 kHz, and ranged from 10–30 dB for the frequencies > 5 kHz. The maximum ITDs were dependent on frequency, yielding 236 μs at 4 kHz and 336 μs at 250 Hz. Removal of the pinnae eliminated the spectral notch cues, reduced the acoustic gain and the ILDs, altered the acoustic axis, and reduced the ITDs.
Mechanical stimulation of the RW in an animal model of SF generates functionally similar inputs to the cochlea as normal acoustic and RW mechanical inputs but with increased thresholds. With further study, AMEIs may provide a surgical option for correction of otosclerosis and ossicular chain disruption.
Conductive hearing loss (CHL) is known to produce hearing deficits, including deficits in sound localization ability. The differences in sound intensities and timing experienced between the two tympanic membranes are important cues to sound localization (ILD and ITD, respectively). Although much is known about the effect of CHL on hearing levels, little investigation has been conducted into the actual impact of CHL on sound location cues. This study investigated effects of CHL induced by earplugs on cochlear microphonic (CM) amplitude and timing and their corresponding effect on the ILD and ITD location cues. Acoustic and CM measurements were made in 5 chinchillas before and after earplug insertion, and again after earplug removal using pure tones (500 Hz to 24 kHz). ILDs in the unoccluded condition demonstrated position and frequency dependence where peak far-lateral ILDs approached 30 dB for high frequencies. Unoccluded ear ITD cues demonstrated positional and frequency dependence with increased ITD cue for both decreasing frequency (± 420 µs at 500 Hz, ± 310 µs for 1–4 kHz ) and increasingly lateral sound source locations. Occlusion of the ear canal with foam plugs resulted in a mild, frequency-dependent conductive hearing loss of 10–38 dB (mean 31 ± 3.9 dB) leading to a concomitant frequency dependent increase in ILDs at all source locations. The effective ITDs increased in a frequency dependent manner with ear occlusion as a direct result of the acoustic properties of the plugging material, the latter confirmed via acoustical measurements using a model ear canal with varying volumes of acoustic foam. Upon ear plugging with acoustic foam, a mild CHL is induced. Furthermore, the CHL induced by acoustic foam results in substantial changes in the magnitudes of both the ITD and ILD cues to sound location.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.