SummaryBackgroundObjective lameness assessment is gaining more importance in a clinical setting, necessitating availability of reference values.ObjectivesTo investigate the between ‐path, ‐trial and ‐day variation, between and within horses, in the locomotion symmetry of horses in regular use that are perceived sound.Study designObservational study with replicated measurement sessions.MethodsTwelve owner‐sound horses were trotted on the straight line and on the lunge. Kinematic data were collected from these horses using 3D optical motion capture. Examinations were repeated on 12 occasions over the study which lasted 42 days in total. For each horse, measurements were grouped as five replicates on the first and second measurement days and two replicates on the third measurement day. Between measurement days 2 and 3, every horse had a break from examination of at least 28 days. Previously described symmetry parameters were calculated: RUD and RDD (Range Up/Down Difference; difference in upward/downward movement between right and left halves of a stride); MinDiff and MaxDiff (difference between the two minima/maxima of the movement); HHDswing and HHDstance (Hip Hike Difference‐swing/‐stance; difference between the upward movement of the tuber coxae during swingphase/stancephase). Data are described by the between‐measurement variation for each parameter. A linear mixed model was used to test for the effect of time, surface and path. Intraclass correlation coefficients (ICC) were calculated to access repeatability.ResultsMean between‐measurement variation was (MinDiff, MaxDiff, RUD, RDD): 13, 12, 20, 16 mm (head); 4, 3, 6, 4 mm (withers) and 5, 4, 6, 6 mm (pelvis); (HHDswing, HHDstance): 7 and 7 mm. More between‐measurement variation is seen on the first measurement day compared to the second and third measurement days. In general, less variation is seen with increasing number of repetitions. Less between‐measurement variation is seen on hard surface compared to soft surface. More between‐measurement variation is seen on the circle compared to the straight line. Between‐horse variation was clearly larger than within‐horse variation. ICC values for the head, withers and pelvis symmetry parameters were 0.68 (head), 0.76 (withers), 0.85 (pelvis).Main limitationsLunge measurements on a hard surface were not performed.ConclusionsBetween‐measurement variation may be substantial, especially in head motion. This should be considered when interpreting clinical data after repeated measurements, as in routine lameness assessments.
Clinical assessment of spinal motion in horses is part of many routine clinical exams but remains highly subjective. A prerequisite for the quantification of spinal motion is the assessment of the expected normal range of motion and variability of back kinematics. The aim of this study was to objectively quantify spinal kinematics and between-measurement,-surface and-day variation in owner-sound horses. In an observational study, twelve ownersound horses were trotted 12 times on four different paths (hard/soft straight line, soft lunge left and right). Measurements were divided over three days, with five repetitions on day one and two, and two repetitions on day three (recheck) which occurred 28-55 days later. Optical motion capture was used to collect kinematic data. Elements of the outcome were: 1) Ranges of Motion (ROM) with confidence intervals per path and surface, 2) a variability model to calculate between-measurement variation and test the effect of time, surface and path, 3) intraclass correlation coefficients (ICC) to determine repeatability. ROM was lowest on the hard straight line. Cervical lateral bending was doubled on the left compared to the right lunge. Mean variation for the flexion-extension and lateral bending of the whole back were 0.8 and 1 degrees. Pelvic motion showed a variation of 1.0 (pitch), 0.7 (yaw) and 1.3 (roll) degrees. For these five parameters, a tendency for more variation on the hard surface and reduced variation with increased repetitions was observed. More variation was seen on the recheck (p<0.001). ICC values for pelvic rotations were between 0.76 and 0.93, for the whole back flexion-extension and lateral bending between 0.51 and 0.91. Between-horse variation was substantially higher than within-horse variation. In conclusion, ROM and variation in spinal biomechanics are horse-specific and small, necessitating individual analysis and making subjective and objective clinical assessment of spinal kinematics challenging.
This is an open access article under the terms of the Creat ive Commo ns Attri butio n-NonCo mmerc ial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
Background:The increasing popularity of objective gait analysis makes application in prepurchase examinations (PPE) a logical next step. Therefore, there is a need to have more understanding of asymmetry during a PPE in horses described on clinical evaluation as subtly lame.Objectives: To objectively compare asymmetry in horses raising minor vet concerns in a PPE and in horses raising major vet concerns with that found in horses presented with subtle single-limb lameness, and to investigate the effect of age/discipline on the clinicians' interpretation of asymmetry on the classification of minor vet concerns in a PPE. Study design: Clinical case-series.Methods: Horses presented for PPE (n=98) or subjectively evaluated as single limb low-grade (1-2/5) lame (n=24, 13 forelimb lame, 11 hindlimb lame), from the patient population of a single clinic, were enrolled in the study provided that owners were willing to participate. Horses undergoing PPE were assigned a classification of having minor vet concerns (n=84) or major vet concerns (n=14) based on findings during the dynamic-orthopaedic part of the PPE. Lame horses were only included if pain-related lameness was confirmed by an objective improvement after diagnostic analgesia exceeding daily variation determined for equine symmetry parameters using optical motion capture. Clinical evaluation was performed by six different clinicians, each with ≥ 8 years of equine orthopaedic experience. Vertical movement symmetry was measured using optical motion capture, simultaneously with the orthopaedic examination. Data were analysed using previously described parameters and mixed model analysis and least squares means were used to calculate differences between groups.Results: There was no effect of age or discipline on the levels of asymmetry within PPE horses raising minor vet concerns. MinDiff and RUD of the head discriminated between forelimb lame and PPE horses raising minor vet concerns; MinDiff, MaxDiff, RUD of the Pelvis, HHDswing and Accepted ArticleThis article is protected by copyright. All rights reserved HHDstance did so for hindlimb lameness. Two lameness patterns differentiated both fore-and hindlimb lame from PPE horses with minor vet concerns: and + ℎ -+ -. Correcting for vertical range of motion enabled differentiation of PPE horses with minor ℎ vet concerns from PPE horses with major vet concerns. Main limitations: Objective data only based on trot on soft surface, limited number of PPE horses with major vet concerns. Conclusions: Combinations of kinematic parameters discriminate between PPE horses with minor vet concerns and subtly lame horses, though overlap exists.
The impact of different acquisition times (AqT) and technetium‐99 m–labeled (99mTc) diphosphonates on the image quality of bone scintigraphy is poorly documented in horses. The aim of this prospective experimental study was to evaluate the impact of varying 99mTc‐disphosphonates and AqT on semiquantitative and qualitative image parameters of bone scintigraphy in horses. Twenty‐four horses undergoing bone scintigraphy were divided equally and randomly into methylene‐ (MDP), hydroxymethylene‐ (HDP), and dicarboxypropane diphosphonate (DPD) groups. Lateral scintigraphic images of the antebrachium were obtained 3 h post 99mTC‐diphosphonate injection using three AqT (60, 90, 120 s). The images were analyzed semiquantitatively using the bone‐soft tissue ratio (B:ST), signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and image contrast. Furthermore, a blinded qualitative analysis was performed using a visual grading analysis. The results showed that DPD images had a significantly higher B:ST ratio than MDP images (P < .01) but not HDP images in all AqT (P > .08). However, DPD and HPD images acquired at 60 s had significantly higher CNR (P < .05) than those acquired at 90 and 120 s. The qualitative analysis revealed no significant differences between 99mTc‐diphosphonates at AqT 60 and 90 s. However, MDP images acquired at 120 s had significantly lower image quality compared to DPD and HDP (P = .01 and .03, respectively). In conclusion, the bone tracers affected the semiquantitative image parameters but not the qualitative analysis findings. Increasing AqT did not necessarily improve the image quality. Therefore, decreasing the AqT enabled a reduction in personnel radiation exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.