Background Endoscopic treatment of esophageal leaks, mostly by covered stents or endoscopic vacuum therapy (EVT), has largely improved the clinical outcome in the last decade. However, both techniques suffer from significant limitations. Covered stents are hampered by a high rate of migration and missing functional drainage, whereas endoluminal EVT devices are limited by obstruction of the GI tract. The new design of the VACStent makes it a fully covered stent within a polyurethane sponge cylinder, allowing EVT while stent passage is still open. Initial clinical applications have demonstrated the fundamental concept of the VACStent. Method A prospective multicenter open-label study was performed with the primary endpoint safe practicality, complete leak coverage, and effective suction-treatment of esophageal leaks. Secondary endpoints were prevention of septic conditions, successful leak healing, and complications, in particular stent-migration, local erosions and bleeding. Results Fifteen patients with different, mostly postoperative anastomotic leaks were enrolled in three centers. A total of 41 VACStents were implanted. The mean number of VACStents per patient was 2.7, with a mean duration of VACStent treatment of 15 days. The primary endpoint was met in all VACStent applications (41/41 implants), resulting in a leak healing rate of 80% (12/15 patients). Septic episodes were prevented in 93% (14/15 patients) and there was no mortality. There were no severe device-related adverse events (SADE) nor significant local bleeding or erosion. Minor stent-dislocation and migration, respectively, was observed in 7%. Oral intake of liquids or food was documented in 87% (13/15 patients). One anastomotic stenosis was seen during follow-up. Conclusions VACStent treatment is a safe and effective treatment in esophageal leaks which can be covered by the sponge cylinder. Its application was described as easy and resembling that of conventional GI stents, with an impressive clinical success rate comparable to EVT outcomes. The VACStent offers a new option for clinical treatment of critical situations in esophageal perforations and anastomotic sutureline failures.
BackgroundInguinal hernia repair is one of the most common surgical operations globally; more than 20 million groin herniae are repaired annually worldwide. Recurrence after an inguinal hernia operation is a considerable clinical problem. Another remaining problem after hernia surgery is the occurrence of chronic pain. Up to now, the use of synthetic meshes is the standard procedure, but there is increasing evidence that biological meshes could be advantageous concerning the occurrence of chronic pain due to different postoperative remodeling, without the disadvantages of a life-long implant.We hypothesize that the use of a biological mesh reduces postoperative pain without being inferior in terms of recurrence rate compared with a synthetic mesh.Methods/designThe trial compares possible the advantages of biological matrices to synthetic meshes in laparo-endoscopic inguinal hernia repair. Four hundred and ninety-six patients with primary bilateral inguinal herniae in 20 German hernia centers will be enrolled. Biological mesh is used for one of the bilateral herniae, the other side will be operated on with a synthetic mesh. Randomization will preset which side is repaired with which material and trial participants will not be informed about the location of each mesh type. The primary endpoints will be intensity of postoperative local pain and the incidence of recurrent hernia after 2 years.DiscussionThere is no reasonably sized trial that assesses the use of biological meshes in laparo-endoscopic inguinal hernia repair.Our self-controlled trial design allows a direct comparison of the two meshes with very few confounding factors as well as minimizing the exclusion criteria. As we compare CE-certified medical devices in their designated indication the medical risk is not different compared to routine clinical care. Due to the common nature of bilateral inguinal hernia, a high recruitment rate is achievable. Because guidelines for hernia repair have stressed the need for reliable data on the already frequent use of biological meshes, we can expect our trial to have a direct implication on hernia-repair standards.Trial registrationGerman Clinical Trials Register, ID: DRKS00010178. Registered on 16.June.2016. BIOLAP underwent full external peer review as part of the funding process with the German Research Foundation.Electronic supplementary materialThe online version of this article (10.1186/s13063-018-3122-5) contains supplementary material, which is available to authorized users.
IntroductionEndoscopic vacuum therapy (EVT) has emerged as a promising treatment option for upper gastrointestinal wall defects, offering benefits such as evacuation of secretions and removal of wound debris by suction, and reduction and healing of wound cavities to improve clinical outcomes. In contrast, covered stents have a high rate of migration and lack functional drainage, while endoluminal EVT devices obstruct the GI tract. The VACStent is a novel device that combines the benefits of EVT and stent placement. Its design features a fully covered Nitinol-stent within a polyurethane sponge cylinder, enabling EVT while maintaining stent patency.MethodsThis study analyzes the pooled data from three different prospective study cohorts to assess the safe practicality of VACStent placement, complete leak coverage, and effective suction-treatment of esophageal leaks. By pooling the data, the study aims to provide a broader base for analysis.ResultsIn total, trans-nasal derivation of the catheter, suction and drainage of secretion via vacuum pump were performed without any adversity. In the pooled study cohort of 92 VACStent applications, the mean stent indwelling time was 5.2 days (range 2–8 days) without any dislocation of the device. Removal of the VACStent was done without complication, in one case the sponge was lost but subsequently fully preserved. Minor local erosions and bleeding and one subsequent hemostasis were recorded unfrequently during withdrawal of the device (5.4%, 5/92) but no perforation or pressure ulcer. Despite a high heterogeneity regarding primary disease and pretreatments a cure rate of 76% (38/50 patients) could be achieved.DiscussionIn summary, insertion and release procedure was regarded as easy and simple with a low potential of dislocation. The VACStent was well tolerated by the patient while keeping the drainage function of the sponge achieving directly a wound closure by continuous suction and improving the healing process. The implantation of the VACStent provides a promising new procedure for improved clinical treatment in various indications of the upper gastrointestinal wall, which should be validated in larger clinical studies.Clinical Trial Registration: Identifier [DRKS00016048 and NCT04884334].
IntroductionEndoscopic treatment by vacuum therapy (EVT) or covered stents has emerged as an improved treatment option for upper gastrointestinal wall defects and is regarded as an improved treatment option for anastomotic leakage (AL) after esophagectomy. However, endoluminal EVT devices may lead to obstruction of the GI tract; and a high rate of migration and missing functional drainage has been shown for covered stents. The recently developed VACStent, a combination of a fully covered stent within a polyurethane sponge cylinder may overcome these issues allowing EVT while stent passage is still open. Initial clinical applications have demonstrated efficacy, practicability and safety in the treatment of esophageal leaks (AL).MethodsIn this pilot study, 9 patients with high-risk anastomosis after neoadjuvant therapy undergoing hybrid esophagectomy received the VACStent in a preemptive setting for the assessment of the reduction of the AL rate, postoperative morbidity and mortality.ResultsTechnical success of the application of the VACStent® was achieved in all interventions. One patient experienced anastomotic leakage 10 days after esophagectomy and was successfully treated with two consecutive VACStents and a VAC Sponge. In summary, mortality in-hospital was 0% and anastomotic healing was uneventful without septic episodes. No severe device-related adverse events (SADE) nor significant local bleeding or erosion could be observed. Oral intake of liquids or food was documented in all patients. The device handling was regarded uncomplicated.DiscussionThe preemptive application of the VACStent offers a promising new option for improved clinical treatment avoiding of critical situations in hybrid esophagectomy, which should be validated in a large clinical study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.