An organic light-emitting device (OLED) with an Al/NaF (1.5 nm) cathode exhibited a highly enhanced performance comparable to the one with the best Al/LiF cathode. This suggests that NaF can be an alternative to commonly used LiF interlayer for improved OLED performance. Photoelectron spectroscopy studies revealed that the intensity of the gap states and the amount of the valence band shift at Al/NaF/Alq3 interface surpassed those of Al/LiF/Alq3 interface, suggesting that the observed performance improvement is directly related with these features.
Articles you may be interested inElectronic, magnetic, and physical structure of cobalt deposited on aluminum tris(8-hydroxy quinoline)A photoelectron spectroscopy study of tunable charge injection barrier between metal/organic interface Appl. Phys. Lett. 93, 023302 (2008); 10.1063/1.2957979Photoemission study of tris(8-hydroxyquinoline) aluminum/aluminum oxide/tris(8-hydroxyquinoline) aluminum interface
Abstract. This work reports on the development of a technique for the precise analysis of ambient SF6. This technique, which involves a gas chromatograph/electron capture detector (GC-ECD) coupled with an Activated Alumina-F1 (AA-F1) column, performed well in the measurements, particularly in terms of accuracy, which complies with the World Meteorological Organization (WMO)-recommended compatibility of 0.02 ppt. Compared to the Porapak Q technique, we observed a sharper peak shape for the SF6 stream, which substantiates the improvement in the analytical precision. The traceability to the WMO scale was tested by calibrating the GC-ECD/AA-F1 analyser using five SF6 standards provided by the WMO/Global Atmosphere Watch (GAW) Central Calibration Laboratory (CCL) for SF6 (NOAA, United States of America). After calibration by various methods, the GC-ECD/AA-F1 accurately estimated the mole fraction of SF6 in the working standard prepared by the World Calibration Centre for SF6 operated by the Korea Meteorological Administration (KMA)/Korea Research Institute of Standards and Science (KRISS). Among the calibration methods, the two-point calibration method emerged to be the most economical procedure in terms of the data quality and measurement time. It was found that the KRISS scale of SF6/N2 was biased by 0.13 ppt when compared to the WMO scale of SF6/air; this bias is probably due to a different matrix.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.