LNE-LNHB is involved in a European project aiming at establishing absorbed dose-to-water standards for photon-radiation fields down to 2 × 2 cm². This requires the calibration of reference ionization chambers of small volume. Twenty-four ionization chambers of eight different types with volume ranging from 0.007 to 0.057 cm³ were tested in a ⁶⁰Co beam. For each chamber, two major characteristics were investigated: (1) the stability of the measured current as a function of the irradiation time under continuous irradiation. At LNE-LNHB, the variation of the current should be less than ±0.1% in comparison with its first value (over a 16 h irradiation time); (2) the variation of the ionization current with the applied polarizing voltage and polarity. Leakage currents were also measured. Results show that (1) every tested PTW (31015, 31016 and 31014) and Exradin A1SL chambers demonstrate a satisfying stability under irradiation. Other types of chambers have a stability complying with the stability criterion for some or none of them. (2) IBA CC01, IBA CC04 and Exradin A1SL show a proper response as a function of applied voltage for both polarities. PTW, Exradin A14SL and Exradin A16 do not. Only three types of chambers were deemed suitable as reference chambers according to LNE-LNHB requirements and specifications from McEwen (2010 Med. Phys. 37 2179-93): Exradin A1SL chambers (3/3), IBA CC04 (2/3) and IBA CC01 (1/3). The Exradin A1SL type with an applied polarizing voltage of 150 V was chosen as an LNE-LNHB reference chamber type in 2 × 2 cm² radiation fields.
Different measurements of depth-dose curves and dose profiles were performed in heterogeneous phantoms and compared to dose distributions calculated by a Monte Carlo code. These heterogeneous phantoms consisted of lung and/or bone heterogeneities. Irradiations and simulations were carried out for an 18 MeV electron beam and a 12 MV photon beam. Depth-dose curves were measured with Fricke dosimeters and with plane and cylindrical ionization chambers. Dose profiles were measured with a small cylindrical ionization chamber at different depths. The LINAC was modelled using the PENELOPE code and phase space files were used as input data for the calculations of the dose distributions in every simulation. The detectors (Fricke dosimeters and ionization chambers) were not modelled in the geometry. There is generally a good agreement between the measurements and PENELOPE. Some discrepancies exist, near interfaces, between the ionization chamber and PENELOPE due to the attenuation of the lower energy electrons by the wall of the ionization chamber.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.