Sleep quantity and quality were significantly improved with PCV compared to low-PSV. Nocturnal respiratory muscles rest through PCV is recommended to improve sleep in ICU patients with acute-on-chronic respiratory failure.
Noninvasive ventilation failure is associated with higher mortality, but is merely a marker of progression of a more severe disease. This may at least indicate the need for caution in some patients. Interestingly, increased use of fiberoptic bronchoscopies during noninvasive ventilation appliance was identified as a risk factor of failure.
Background: Predicted postoperative FEV1 (ppoFEV1) must be estimated preoperatively prior to surgery for non-small cell lung cancer (NSCLC). We evaluated a lung volumetry approach based on chest computed tomography (CT).Methods: A prospective study was conducted over a period of one year in eligible lung cancer patients to evaluate the difference between ppoFEV1 and the 3-month postoperative FEV1 (poFEV1). Patients in whom CT was performed in another hospital and those with factors influencing poFEV1, such as atelectasis, pleural effusion, pneumothorax, or pneumonia, were excluded. A total of 23 patients were included and ppoFEV1 was calculated according to 4 usual Methods: Nakahara formula, Juhl and Frost formula, ventilation scintigraphy, perfusion scintigraphy, and a fifth method based on quantitative CT. Lung volume was calculated twice and separately by 2 radiologists. Tumor volume, and emphysema defined by a −950 HU limit were subtracted from the total lung volume in order to estimate ppoFEV1.
Results:We compared 5 methods of ppoFEV1 estimation and calculated the mean volume difference between ppoFEV1 and poFEV1. A better correlation was observed for quantitative CT than for Nakahara formula, Juhl and Frost formula, perfusion scintigraphy and ventilation scintigraphy with respectively: R²=0.79 vs. 0.75, 0.75, 0.67 and 0.64 with a mean volume difference of 266±229 mL (P<0.01) vs. 320±262 mL (P<0.01), 332±251 mL (P<0.01), 304±295 mL (P<0.01) and 312±303 mL (P<0.01).Conclusions: Quantitative CT appears to be a satisfactory method to evaluate ppoFEV1 evaluation method, and appears to be more reliable than other approaches. Estimation of ppoFEV1, as part of the preoperative assessment, does not involve additional morphologic examinations, particularly scintigraphy.This method may become the reference method for ppoFEV1 evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.