Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT us ) and a priori CT-based scatter correction (CBCT ap ). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT us , while no HU change was applied to the CBCT ap . The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT ref ) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT ap was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT us images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT ref , while the CBCT ap images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT ap -based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms. C 2015 American Association of Physicists in Medicine. [http://dx
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ∼4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 × 10 12 positrons were accumulated and together the data yield a muon lifetime of τµ(MuLan) = 2 196 980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant GF (MuLan) = 1.166 378 7(6) × 10 −5 GeV −2 (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 × 10 12 decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give τ µ + (MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: GF (MuLan) = 1.1663788(7) × 10 −5 GeV −2 (0.6 ppm). It is also used to extract the µ − p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g P .A measurement of the positive muon lifetime, τ µ + , to high precision determines the Fermi constant, G F , according to the relationHere, ∆q represents well-known phase space and both QED and hadronic radiative corrections [1], and we assume that G F is universal for weak interactions. Strictly speaking, τ µ + determines a muon-decay-specific coupling, denoted G µ , which could be compared to other G F determinations as a test of the standard model [2]. Prior to 1999, the limitation on the precision of G F was dominated by the uncertainty on ∆q. Van Ritbergen and Stuart were the first to compute the secondorder QED radiative corrections in the massless electron limit, reducing the theoretical uncertainty to below 0.3 ppm [3], and well below the then-current experimental uncertainty. This development motivated a new generation of precision muon lifetime measurements, MuLan [4] and FAST [5]. More recently, Pak and Czarnecki extended the result in [3] to finite electron mass, which shifts the predicted decay rate 1/τ µ by -0.43 ppm; alternatively, it decreases G F by 0.21 ppm [6].In Ref.[4], we reported an 11 ppm measurement of τ µ + based on a relatively short commissioning run. This Letter reports the results from a 100 times larger data set, accumulated using the final setup of the experiment.The experiment is designed to stop muons in a target during a beam-on accumulation interval and measure the decay positrons-primarily from the µ + → e + ν eνµ decay mode-during a beam-off measurement period. The two running periods, R06 and R07, used different targets. More than 10 12 decays were recorded in each period.The experiment used the πE3 beamline at the Paul Scherrer Institute (PSI). During the run, positive muons from at-rest pion decay near the surface of the production target are directed to the experiment through two opposing vertical dipole magnets and a series of 15 magnetic quadrupole lenses. A velocity-selecting E × B separator is tuned to pass muons and reject positrons. A special feature of the beamline is a custom, 60-ns switching, 25-kV kicker [8]. When energized, the electric field across the 120-mm vertical gap and 1500-mm length displaces the muon beam by 46 mm at the exit and deflects it by 45 mrad onto a downstream collimator. The muon flux of ∼ 1...
We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 × 10 12 decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give τ µ + (MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: GF (MuLan) = 1.1663788(7) × 10 −5 GeV −2 (0.6 ppm). It is also used to extract the µ − p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g P .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.