The adsorption isotherm of cadmium on activated carbon was measured in a batch adsorber. Effects of temperature and solution pH on the adsorption isotherm were investigated by determining the adsorption isotherm at temperatures of 10, 25, and 40°C and at initial pH values from 2 to 8. Langmuir isotherm better fitted the experimental data since the average percent deviation was lower than with the Freundlich isotherm It was noticed that the amount of Cd2+ adsorbed was reduced about 3 times by increasing the temperature from 10 to 40°C. It was found that Cd2+ was not adsorbed on activated carbon at pH of 2 or lower and that Cd2+ was precipitated out as Cd(OH)2 at pH values above 9. Maximum adsorption capacity was observed at pH of 8 and the adsorption capacity was decreased about 12 times by reducing the initial pH from 8 to 3. According to the cadmium speciation diagram the predominant species below pH of 8 is Cd2+. Thus, cadmium was adsorbed on the activated carbon surface as Cd2+. It was concluded that the adsorption capacity is a strong function of pH and temperature.
Equilibrium and dynamic adsorption of heavy metals onto spent coffee ground (SCG) were studied. The equilibrium adsorption of Cd2+, Cu2+, and Pb2+in a batch system was modeled by an ion-exchange model (IEM) based on an ion-exchange of heavy metals with calcium and protons bonded to active sites on SCG surface. The maximum amount of adsorbed metal ions obtained using the IEM was 0.12, 0.21, and 0.32 mmol/g of Cd2+, Cu2+, and Pb2+, respectively. Regeneration of SCG was evaluated using citric acid, calcium chloride, and nitric acid. The observed trend of desorption efficiency through four adsorption-desorption cycles was HNO3> CaCl2> C6H8O7. The effect of process variables such as flow rate and bed height during the dynamic adsorption was evaluated. Moreover, the applicability of a mass transfer model based on external mass transfer resistance, axial dispersion, and ion-exchange isotherm was evaluated, and the results were in good agreement with the experimental data for the adsorption in SCG packed column. The sensitivity analysis of the model parameters showed that axial dispersion coefficient is the most significant parameter in the dynamic simulation. The results obtained showed the potential of SCG as a low-cost material for wastewater metal removal in continuous systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.