Aim:The purpose of this study was to evaluate the effects of three electronic apex locators (EAL), electric pulp tester (EPT) and diathermy on pacemaker function in vitro.Materials and Methods:Three EALs: Root ZX (J. Morita Co., Tustin, CA, U.S.A.), Propex (Dentsply), Mini Apex locator (SybronEndo, Anaheim, CA, USA), EPT (Parkell pulp vitality tester Farmingdale, NY, USA) and Diathermy (Neomed 250 B) were tested for any interference with one pacemaker (A medtronic kappa KVDD901-serial number: PLE734632S). Directly connecting the pacemaker lead with the EAL/EPT/diathermy operating on a flat bench top, the telemetry wand was held directly over the pacemaker to monitor the pacing pattern for a period of 30 s. Pacemaker activity was continuously recorded on the telemetric programmer and electro gram (EGM) readings examined for pacer inhibition, noise reversion or inappropriate pacemaker pulses.Results:All the three apex locators showed no pacing interference or background noise during its function or at rest. The EGM readings of EPT showed varying levels of background noise in between pacing however, this did not affect the normal pacing pattern and the pacing interval remained constant. EGM readings of diathermy showed an increase in the pacing interval (irregular pacing pattern) followed by complete inhibition of the pacing system.Conclusion:The tested EALs do not interfere with cardiac pacemaker function. The tested EPT showed varying levels of background noise but does not interfere with cardiac pacemaker function. Use of Diathermy interfered with the normal pacing, leading to complete inhibition of the pacing system.
This is a retrospective study documenting the use of tenecteplase in 41 cases of suspected or confirmed pulmonary embolism receiving in-hospital tenecteplase as per weight-adjusted dosing in addition to standard heparin and oral anticoagulant therapy. The presenting symptoms of dyspnoea, chest pain, hemoptysis and syncope were found in 40 (97.56%), 19 (46.34%), 6 (14.63%) and 9 (21.95%) patients, respectively. There was one case of mortality who was a 26 yrs old female of postpartum pulmonary thrombo-embolism with severe hypotension, cyanosis, bilateral crepitations in lungs and pulmonary hypertension. In the 40 survived patients, there was alleviation of dyspnoea and hemoptysis in all patients. Significant reduction in tachycardia (P < 0.0001) and increase in the oxygen saturation (SaO₂) (P < 0.0001) were seen at discharge as compared to at the time of presentation. Eighteen patients had hypotension which recovered in all patients till the time of discharge (P < 0.0001). There was a significant reduction in right ventricular systolic pressure in all 18 patients who underwent 2-D echocardiography both before and after the tenecteplase therapy. Resolution of pulmonary embolism on CT pulmonary angiography was documented in only two patients. No bleeding events or any other adverse events were reported during this study. The present study suggests favourable efficacy of tenecteplase in patients with suspected or confirmed acute pulmonary embolism. Although no major adverse events were noted, a large prospective study on the use of tenecteplase in pulmonary embolism is suggested.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.