Summary The practice has developed in recent years of constructing statically indeterminate prestressed concrete structures by applying connecting restraints to two or more statically determinate prestressed concrete members. The present paper discusses a joint that may be used to convert two or more simply supported prestressed concrete beams into a continuous beam by joining them together over the supports. This joint utilizes unprestressed continuity steel contained within the crosssection of the continuous beam. Alternative designs for such a joint are proposed and examined for suitability in fulfilling the necessary functions. Some remarks are added on the design of composite continuous beams. Tests are reported on five two-span composite beams each made from two post-tensioned, grouted beams. The ratio of the ultimate moments of resistance of the critical sections was varied. The tests demonstrated the essentially satisfactory nature of the proposed joint.
The paper by Mr Reeves and Professor Morice provides further support for the use of reinforced concrete joints between prestressed concrete members. In their discussion of joint design, and specifically of the behaviour of this type of joint at ultimate load, the authors suggest that, at transfer of prestress, the stresses in the lower fibres of the span members at sections adjacent to the supports should be low compressive or tensile stresses. Tests of joints of the type shown in Figure lc of the paper, recently carried out in the Structural Development Laboratory of the Portland Cement Association (1), have shown that this requirement is not always necessary.Pairs of precast prestressed I beams were joined together by deformed reinforcing bars placed longitudinally across the joint in a deck slab cast on top of the girders, as shown in Figure I. The space between the ends of the girders was filled by concrete forming part of a transverse diaphragm placed at the joint. The specimens were supported below the joint and loaded by equal point loads at each end. In these tests, the amount of normal reinforcing bars in the deck slab, expressed as a percentage of (depth of girder x width of bottom flange), was 0·83, 1·66 or 2·49 /~. The initial precompression of the bottom flange of the pr,ecast girders was 0, 2,100 or 3,100 Ibjin 2 • The ultimate strength of each connexion measured in the tests was compared with the calculated ultimate strength, any influence of precompression of the bottom flange of the precast member being neglected, and also with the calculated ultimate strength taking this precompression into account. From a study of these measured and calculated ultimate strengths it was concluded that, for the practical range of continuity reinforcement of from 0·5 to 1·5 %, the influence of precompression of the bottom flange may be neglected in the calculation of the ultimate strength of this type of joint. These tests and the conclusions drawn from them are discussed fully in PCA Development Department Bulletin D34(1).Similar tests have been carried out on connexions between prestressed double-T members (2), in which deformed bars were placed in the topping concrete ·Pages 13-20 of Magazine No. 37. 160 covering the top flange of the member. Equally favourable results were obtained in these tests.The behaviour of this type of connexion has also been studied in tests of continuous composite beams(1-4), and has been found to be most satisfactory. One of these tests is seen in progress in Figure II. The specimen consists of two 33-ft long precast prestressed I beams joined by deformed bars placed in a 39 x 3 in. thick cast-in-place concrete deck slab. The beam is a half-scale model of one beam and its portion of deck slab taken from a two-span continuous highway bridge. The beam was designed for the envelope of maximum moments caused by the standard H20-S16 loading of the American Association of State Highway Officials. The test loading simulated the equivalent H20-S16 lane loading, arranged so as to cause maximu...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.