Soft and conductive nanomaterials like carbon nanotubes, graphene, and nanowire scaffolds have expanded the family of ultraflexible microelectrodes that can bend and flex with the natural movement of the brain, reduce the inflammatory response, and improve the stability of long-term neural recordings. However, current methods to implant these highly flexible electrodes rely on temporary stiffening agents that temporarily increase the electrode size and stiffness thus aggravating neural damage during implantation, which can lead to cell loss and glial activation that persists even after the stiffening agents are removed or dissolve. A method to deliver thin, ultraflexible electrodes deep into neural tissue without increasing the stiffness or size of the electrodes will enable minimally invasive electrical recordings from within the brain. Here we show that specially designed microfluidic devices can apply a tension force to ultraflexible electrodes that prevents buckling without increasing the thickness or stiffness of the electrode during implantation. Additionally, these "fluidic microdrives" allow us to precisely actuate the electrode position with micron-scale accuracy. To demonstrate the efficacy of our fluidic microdrives, we used them to actuate highly flexible carbon nanotube fiber (CNTf) microelectrodes for electrophysiology. We used this approach in three proof-of-concept experiments. First, we recorded compound action potentials in a soft model organism, the small cnidarian Hydra. Second, we targeted electrodes precisely to the thalamic reticular nucleus in brain slices and recorded spontaneous and optogenetically evoked extracellular action potentials. Finally, we inserted electrodes more than 4 mm deep into the brain of rats and detected spontaneous individual unit activity in both cortical and subcortical regions. Compared to syringe injection, fluidic microdrives do not penetrate the brain and prevent changes in intracranial pressure by diverting fluid away from the implantation site during insertion and actuation. Overall, the fluidic microdrive technology provides a robust new method to implant and actuate ultraflexible neural electrodes.
The development of efficient and biocompatible non-viral vectors for gene therapy remains a great challenge, and exploiting the properties of both nanoparticle carriers and cationic polymers is an attractive approach. In this work, we have developed gold nanoparticle (AuNP) polyamidoamine (PAMAM) conjugates for use as non-viral transfection agents. AuPAMAM conjugates were prepared by crosslinking PAMAM dendrimers to carboxylic-terminated AuNPs via EDC and sulfo-NHS chemistry. EDC and sulfo-NHS have been utilized widely and in numerous applications such as amino acid coupling; however, their use in the coupling of PAMAM dendrimers to AuNPs presents new challenges to form effective and stable constructs for delivery that have not yet been examined. Enhanced colloidal stability and DNA condensation ability was established by probing two critical synthetic parameters: the reaction rate of the PAMAM crosslinking step, and the amine to carboxyl ratio. Based on this work, increasing the amine to carboxyl ratio during conjugation of PAMAM onto AuNPs yielded the optimal vector with respect to colloidal stability and transfection efficiency in vitro. AuPAMAM conjugates present attractive candidates for non-viral gene delivery due to their commercial availability, ease of fabrication and scale-up, high yield, high transfection efficiency and low cytotoxicity.
Smart wearable electronic accessories (e.g., watches) have found wide adoption; conversely, progress in electronic textiles has been slow due to the difficulty of embedding rigid electronic materials into flexible fabrics. Electronic clothing requires fibers that are conductive, robust, biocompatible, and can be produced on a large scale. Here, we create sewable electrodes and signal transmission wires from neat carbon nanotube threads (CNTT). These threads are soft like standard sewing thread, but they have metal-level conductivity and low interfacial impedance with skin. Electrocardiograms (EKGs) obtained by CNTT electrodes were comparable (P > 0.05) to signals obtained with commercial electrodes. CNTT can also be used as transmission wires to carry signals to other parts of a garment. Finally, the textiles can be machine-washed and stretched repeatedly without signal degradation. These results demonstrate promise for textile sensors and electronic fabric with the feel of standard clothing that can be incorporated with traditional clothing manufacturing techniques.
Carbon-based materials (CBMs), such as graphene, nanodiamonds, carbon fibers, and carbon dots, have attracted a great deal scientific attention due to their potential as biomedical tools. Following exposure, particularly intravenous injection, these nanomaterials can be recognized by immune cells. Such interactions could be modulated by the different physicochemical properties of the materials (e.g. structure, size, and chemical functions), by either stimulating or suppressing the immune response. However, a harmonized cutting-edge approach for the classification of these materials based not only on their physicochemical parameters but also their immune properties has been missing. The European Commission-funded G-IMMUNOMICS and CARBO-IMmap projects aimed to fill this gap, developing a functional pipeline for the qualitative and quantitative immune characterization of graphene, graphene-related materials (GRMs), and other CBMs. The goal was to open breakthrough perspectives for the definition of the immune profiles of these materials. Here, we summarize our methodological approach, key results, and the necessary multidisciplinary expertise ranging across various fields, from material chemistry to engineering, immunology, toxicology, and systems biology. G-IMMUNOMICS, as a partnering project of the Graphene Flagship, the largest scientific research initiative on graphene worldwide, also complemented the studies performed in the Flagship on health and environmental impact of GRMs. Finally, we present the nanoimmunity-by-design concept, developed within the projects, which can be readily applied to other 2D materials. Overall, the G-IMMUNOMICS and CARBO-IMmap projects have provided new insights on the immune impact of GRMs and CBMs, thus laying the foundation for their safe use and future translation in medicine.
Background: Impaired myocardial conduction is the underlying mechanism for re-entrant arrhythmias. Carbon nanotube fibers (CNTfs) combine the mechanical properties of suture materials with the conductive properties of metals and may form a restorative solution to impaired myocardial conduction. Methods: Acute open chest electrophysiology studies were performed in sheep (n=3). Radiofrequency ablation was used to create epicardial conduction delay after which CNTf and then silk suture controls were applied. CNTfs were surgically sewn across the right atrioventricular junction in rodents, and acute (n=3) and chronic (4-week, n=6) electrophysiology studies were performed. Rodent toxicity studies (n=10) were performed. Electrical analysis of the CNTf-myocardial interface was performed. Results: In all cases, the large animal studies demonstrated improvement in conduction velocity using CNTf. The acute rodent model demonstrated ventricular preexcitation during sinus rhythm. All chronic cases demonstrated resumption of atrioventricular conduction, but these required atrial pacing. There was no gross or histopathologic evidence of toxicity. Ex vivo studies demonstrated contact impedance significantly lower than platinum iridium. Conclusions: Here, we show that in sheep, CNTfs sewn across epicardial scar acutely improve conduction. In addition, CNTf maintain conduction for 1 month after atrioventricular nodal ablation in the absence of inflammatory or toxic responses in rats but only in the paced condition. The CNTf/myocardial interface has such low impedance that CNTf can facilitate local, downstream myocardial activation. CNTf are conductive, biocompatible materials that restore electrical conduction in diseased myocardium, offering potential long-term restorative solutions in pathologies interrupting efficient electrical transduction in electrically excitable tissues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.