Although a small number of patients were treated, this study provides radiological and histological evidence in humans confirming the suitability of this new BCP for vertical augmentation of the atrophied maxilla by means of a maxillary sinus floor elevation procedure allowing subsequent dental implant placement after a 6-month healing period. The newly formed bone had a trabecular structure and was in intimate contact with the substitute material, outlining the osteoconductive properties of the BCP material. Bone maturation was evident by the presence of lamellar bone.
Objectives: To determine the difference in light reflection of oral mucosa covering titanium (Ti) or zirconia (ZrO2) abutments as it relates to the thickness of the covering mucosa.
Material and methods: Fifteen anterior implants (Astra Osseo speed®) in 11 patients were fitted with a Ti or a ZrO2 abutment (cross‐over, within‐subject comparison). Hyper‐spectral images were taken with a camera fitted on a surgical microscope. High‐resolution images with 70 nm interval between 440 and 720 nm were obtained within 30 s (1392 × 1024 pixels). Black‐ and white‐point reference was used for spatial and spectral normalization as well as correction for motion during exposure. Reflection spectra were extracted from the image on a line mid‐buccal of the implant, starting 1 mm above the soft tissue continuing up to 3 mm apically.
Results: Median soft tissue height is 2.3 mm (min: 1.2 mm and max: 3.1 mm). The buccal mucosa rapidly increases in the thickness, when moving apically. At 2.2 mm, thickness is 3 mm. No perceivable difference between the Ti and ZrO2 abutment can be observed when the thickness of the mucosa is 2±0.1 mm (95% confidence interval) or more.
Conclusion: It is expected that the difference in light reflection of soft tissue covering Ti or ZrO2 abutments is no longer noticeable for the human eye when the mucosa thickness exceeds 2 mm. Haemoglobin peaks in the reflection spectrum can be observed and make hyper‐spectral imaging a practical and useful tool for measuring soft tissue health.
To cite this article:
van Brakel R, Noordmans HJ, Frenken J, de Roode R, de Wit GC, Cune MS. The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues. Clin. Oral Impl. Res. 22, 2011; 1172–1178 doi: 10.1111/j.1600‐0501.2010.02082.x
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.