GVHD (CGVHD) recently proposed criteria for diagnosis and assessment of overall CGVHD severity. We retrospectively reviewed 54 consecutive patients diagnosed with CGVHD between January 2002 and December 2005 after sibling donor transplant to assess the applicability of the new criteria in prognosticating survival and transplant-related mortality (TRM). A total of 8 patients (15%) were reclassified as late onset/ persistent or recurrent acute GVHD (late aGVHD), 15 (28%) had overlap syndrome and 31 (57%) had classic CGVHD. Three-year overall survival was worse in patients with late aGVHD (3-year probability 25% (95% CI 4-56%)) followed by overlap syndrome (3-year probability 87% (95% CI 56-96%)) and CGVHD (3-year probability 75% (95% CI 54-87%)); P ¼ 0.001. Among patients with overlap syndrome and CGVHD, a trend towards worse survival was seen in patients with severe disease (3-year probability 57.3% (95% CI 21-82%)) as compared to mild þ moderate disease (3-year probability 85.1% (95% CI 68-94)); P ¼ 0.1. This analysis, undertaken in a contemporary cohort of related donor recipients, indicates that the consensus guidelines are applicable to this population of CGVHD patients.
Summary High levels of urokinase-type plasminogen activator (uPA) and plasminogen activator inhibitor type 1 (PAI-1) in breast cancer tissue extracts have been associated with rapid disease progression. In these studies, different enzyme-linked immunosorbent assay (ELISA) kits have been applied for the quantification, and consequently the ranges of uPA and PAI-1 levels reported differ considerably. Therefore, the Receptor and Biomarker Study Group (RBSG) of the European Organization for Research and Treatment of Cancer (EORTC) and a consortium of the BIOMED-1 project 'Clinical Relevance of Proteases in Tumor Invasion and Metastasis' initiated three collaborative between-laboratory assessment trials aimed at controlling uPA and PAI-1 antigen analyses. For this purpose, two control preparations were produced from different sources: pooled human breast cancer specimens (QC-240893) and human breast cancer xenografts raised in nude mice (QC-1 01094). The lyophilized preparations were stable for prolonged times (at least 3 and 27 months respectively) at 40C. Furthermore, a good parallelism following dilution was found for uPA and PAI-1. The data from QC trial no. 1 clearly indicated that acceptable betweenlaboratory coefficients of variation (CVs) for uPA (<8.2%) and PAI-1 (<16.6%) in QC-240893 could be achieved when the same type of ELISA kit (American Diagnostica) was used. From the second trial, in which ten EORTC laboratories each received five identical lyophilized QC-101094 samples, it appeared that the within-laboratory variations for uPA and PAI-1 determinations obtained by 'experienced' laboratories were lower (<12.9%) than those from non-experienced laboratories (<36.4%). In a third QC trial, five BIOMED-1 laboratories, all of which employed ELISA procedures for uPA and PAI-1, participated in six subsequent quality assessment rounds receiving five samples of QC-101094. Although for each laboratory the within-run CVs for uPA as well as for PAI-1 were low (<7.8%), the between-run CVs were found to be considerably higher (up to 56.2% for uPA and to 27.6% for PAI-1). Consequently, because of the different ELISA formats used, the absolute analyte values measured in the different laboratories varied substantially. The use of 'common external standards' in the different ELISAs resulted in a significant reduction of the between-laboratory CVs from 61.3% to 15.7% (uPA) and from 42.1% to 19.1% (PAI-1). The present data demonstrate that in multicentre studies the same ELISA kit should be used, and that external quality assurance (QA) is mandatory. Furthermore, it appears from the present study that standardization of the protein assay as a tissular parameter is imperative.Keywords: uPA; PAI-1; enzyme-linked immunosorbent assay; breast cancer; quality assessment; EORTC During the past decade, convincing evidence has accumulated progression and early death (Duffy et al, 1988;Janicke et al, 1990; suggesting that the urokinase-type plasminogen activator (uPA) Foekens et al, 1992, Spyratos et al, 1992Duffy, 1996). plays a k...
SummaryThe prognostic value of tissue-type plasminogen activator (tPA) measured in samples derived from 865 patients with primary breast cancer using a recently developed enzyme-linked immunosorbent assay (ELISA) was evaluated. Since the assay could easily be adapted to the assessment of the complex of tPA with its type-1 inhibitor (PAI-1), it was investigated whether the tPA:PAI-1 complex also provides prognostic information. To this end, cytosolic extracts and corresponding detergent extracts of 100 000 g pellets obtained after ultracentrifugation when preparing the cytosolic fractions for routine steroid hormone receptor determination were assayed. Statistically significant correlations were found between the cytosolic levels and those determined in the pellet extracts (Spearman correlation coefficient r s = 0.75, P < 0.001 for tPA and r = 0.50, P < 0.001 for tPA:PAI-1 complex). In both Cox univariate and multivariate analysis elevated levels of (total) tPA determined in the pellet extracts, but not in cytosols, were associated with prolonged relapse-free (RFS) and overall survival (OS). In contrast, high levels of the tPA:PAI-1 complex measured in cytosols, but not in the pellet extracts, were associated with a poor RFS and OS. The prognostic information provided by the cytosolic tPA:PAI-1 complex was comparable to that provided by cytosolic (total) PAI-1. Furthermore, the estimated levels of free, uncomplexed tPA and PAI-1, in cytosols and in pellet extracts, were related to patient prognosis in a similar way as the (total) levels of tPA and PAI-1 respectively. Determination of specific forms of components of the plasminogen activation system, i.e. tPA:PAI-1 complex and free, uncomplexed tPA and/or PAI-1, may be considered a useful adjunct to the analyses of the separate components (tPA and/or PAI-1) and provide valuable additional prognostic information with respect to survival of breast cancer patients.
Measurement of primary tumor p53 levels may be effective in predicting response to tamoxifen therapy in recurrent breast disease. However, more confirming studies on the association between p53 protein accumulation and response to antiestrogen therapy are needed before tumor p53 levels can be used in routine clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.