BACKGROUND:Endotracheal tube security is a critical safety issue. We compared the mobility of an in situ endotracheal tube secured with adhesive tape to the one secured with a new commercially available purpose-designed endotracheal tube-holder device (Haider Tube-Guard®). We also observed for the incidence of oropharyngeal or facial trauma associated with the 2 tube fixation methods.METHODS:Thirty adult patients undergoing general anesthesia with neuromuscular blockade were prospectively enrolled. Immediately after intubation, a single study author positioned the endotracheal tube tip in the distal trachea using a bronchoscope. Anesthesiologists caring for patients secured the tube in their normal fashion (always with adhesive tape). A force transducer was used to apply linear force, increasing to 15 N or until the principal investigator deemed that the force be aborted for safety reasons. The displacement of the endotracheal tube was measured with the bronchoscope. Any tape was then removed and the endotracheal tube secured with the Haider Tube-Guard device. The linear force was reapplied and the displacement of the endotracheal tube measured. The Haider Tube-Guard device was left in place for the duration of the case. The patient’s face and oropharynx were examined for any evidence of trauma during surgery and in the recovery room. On discharge from the postanesthesia care unit, the patient answered a brief survey assessing for any subjective evidence of minor facial or oropharyngeal trauma.RESULTS:Under standardized tension, the endotracheal tube withdrew a mean distance of 3.4 cm when secured with adhesive tape versus 0.3 cm when secured with the Haider Tube-Guard (P <0.001). Ninety-seven percent of patients (29/30) experienced clinically significant endotracheal tube movement (>1 cm) when adhesive tape was used to secure the tube versus 3% (1/30) when the Haider Tube-Guard was used (P <0.001). Thirty percent of patients (9/30) were potentially deemed a high extubation risk (endotracheal tube movement >4 cm) when the endotracheal tube was secured with tape versus 0% (0/30) when secured with the Haider Tube-Guard (P = 0.004). Six patients with taped endotracheal tubes required the traction to be aborted before 15 N of force was achieved to prevent potential extubation as the tape either separated from the face or stretched to allow excessive endotracheal tube movement. None of the patients appeared to sustain any injury from the Haider Tube-Guard device.CONCLUSIONS:The Haider Tube-Guard significantly reduced the mobility of the endotracheal tube when compared with adhesive tape and was well tolerated in our observations.
Background-This multi-center, retrospective study was conducted to determine how resident performance deficiencies affect graduation and board certification.Methods-Primary documents pertaining to resident performance were examined over a 10year period at four academic anesthesiology residencies. Residents entering training between 2000 and 2009 were included, with follow-up through February 2016. Residents receiving actions by the programs' Clinical Competency Committee were categorized by the area of deficiency and compared to peers without deficiencies.Results-A total of 865 residents were studied (range: 127-275 per program). Of these, 215 residents received a total of 405 actions from their respective Clinical Competency Committee. Among those who received an action compared to those who did not, the proportion graduating differed (93% versus 99%, respectively, P<0.001), as did the proportion achieving board certification (89% versus 99%, respectively, P<0.001). When a single deficiency in an Essential Attribute (e.g., ethical, honest, respectful behavior; absence of impairment) was identified, the proportion graduating dropped to 55%. When more than three Accreditation Council for Graduate Medical Education core competencies were deficient, the proportion graduating also dropped significantly.Conclusions-Overall graduation and board certification rates were consistently high in residents with no, or isolated, deficiencies. Residents deficient in an Essential Attribute, or multiple competencies, are at high risk of not graduating or achieving board certification. More research is needed on the effectiveness and selective deployment of remediation efforts, particularly for high-risk groups.
Background This multicenter, retrospective study was conducted to determine how resident performance deficiencies affect graduation and board certification. Methods Primary documents pertaining to resident performance were examined over a 10-yr period at four academic anesthesiology residencies. Residents entering training between 2000 and 2009 were included, with follow-up through February 2016. Residents receiving actions by the programs’ Clinical Competency Committee were categorized by the area of deficiency and compared to peers without deficiencies. Results A total of 865 residents were studied (range: 127 to 275 per program). Of these, 215 residents received a total of 405 actions from their respective Clinical Competency Committee. Among those who received an action compared to those who did not, the proportion graduating differed (93 vs. 99%, respectively, P < 0.001), as did the proportion achieving board certification (89 vs. 99%, respectively, P < 0.001). When a single deficiency in an Essential Attribute (e.g., ethical, honest, respectful behavior; absence of impairment) was identified, the proportion graduating dropped to 55%. When more than three Accreditation Council for Graduate Medical Education Core Competencies were deficient, the proportion graduating also dropped significantly. Conclusions Overall graduation and board certification rates were consistently high in residents with no, or isolated, deficiencies. Residents deficient in an Essential Attribute, or multiple competencies, are at high risk of not graduating or achieving board certification. More research is needed on the effectiveness and selective deployment of remediation efforts, particularly for high-risk groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.