PurposeTo determine the locus of test locations that exhibit statistically similar age-related decline in sensitivity to light increments and age-corrected contrast sensitivity isocontours (CSIs) across the central visual field (VF). We compared these CSIs with test point clusters used by the Glaucoma Hemifield Test (GHT).MethodsSixty healthy observers underwent testing on the Humphrey Field Analyzer 30-2 test grid using Goldmann (G) stimulus sizes I-V. Age-correction factors for GI-V were determined using linear regression analysis. Pattern recognition analysis was used to cluster test locations across the VF exhibiting equal age-related sensitivity decline (age-related CSIs), and points of equal age-corrected sensitivity (age-corrected CSIs) for GI-V.ResultsThere was a small but significant test size–dependent sensitivity decline with age, with smaller stimuli declining more rapidly. Age-related decline in sensitivity was more rapid in the periphery. A greater number of unique age-related CSIs was revealed when using smaller stimuli, particularly in the mid-periphery. Cluster analysis of age-corrected sensitivity thresholds revealed unique CSIs for GI-V, with smaller stimuli having a greater number of unique clusters. Zones examined by the GHT consisted of test locations that did not necessarily belong to the same CSI, particularly in the periphery.ConclusionsCluster analysis reveals statistically significant groups of test locations within the 30-2 test grid exhibiting the same age-related decline. CSIs facilitate pooling of sensitivities to reduce the variability of individual test locations. These CSIs could guide future structure-function and alternate hemifield asymmetry analyses by comparing matched areas of similar sensitivity signatures.
PurposeGoldmann size V (GV) test stimuli are less variable with a greater dynamic range and have been proposed for measuring contrast sensitivity instead of size III (GIII). Since GIII and GV operate within partial summation, we hypothesise that actual GV (aGV) thresholds could predict GIII (pGIII) thresholds, facilitating comparisons between actual GIII (aGIII) thresholds with pGIII thresholds derived from smaller GV variances. We test the suitability of GV for detecting visual field (VF) loss in patients with early glaucoma, and examine eccentricity‐dependent effects of number and depth of defects. We also hypothesise that stimuli operating within complete spatial summation (‘spatially equated stimuli’) would detect more and deeper defects.MethodsSixty normal subjects and 20 glaucoma patients underwent VF testing on the Humphrey Field Analyzer using GI‐V sized stimuli on the 30‐2 test grid in full threshold mode. Point‐wise partial summation slope values were generated from GI‐V thresholds, and we subsequently derived pGIII thresholds using aGV. Difference plots between actual GIII (aGIII) and pGIII thresholds were used to compare the amount of discordance. In glaucoma patients, the number of ‘events’ (points below the 95% lower limit of normal), defect depth and global indices were compared between stimuli.Results90.5% of pGIII and aGIII points were within ±3 dB of each other in normal subjects. In the glaucoma cohort, there was less concordance (63.2% within ±3 dB), decreasing with increasing eccentricity. GIII found more defects compared to GV‐derived thresholds, but only at outermost test locations. Greater defect depth was found using aGIII compared to aGV and pGIII, which increased with eccentricity. Global indices revealed more severe loss when using GIII compared to GV. Spatially equated stimuli detected the greatest number of ‘events’ and largest defect depth.ConclusionsWhilst GV may be used to reliably predict GIII values in normal subjects, there was less concordance in glaucoma patients. Similarities in ‘event’ detection and defect depth in the central VF were consistent with the fact that GIII and GV operate within partial summation in this region. Eccentricity‐dependent effects in ‘events’ and defect depth were congruent with changes in spatial summation across the VF and the increase in critical area with disease. The spatially equated test stimuli showed the greatest number of defective locations and larger sensitivity loss.
PURPOSE. To investigate the effect of stimulus size and disease status on the structure-function relationship within the central retina, we correlated the differential light sensitivity (DLS) with Goldmann stimulus size I to V (GI-V) and optical coherence tomography (OCT) derived in vivo ganglion cell count per stimulus area (GCc) within the macular area in normal subjects and patients with early glaucoma.METHODS. Humphrey Field Analyzer 10-2 visual field data with GI through V and Spectralis OCT macular ganglion cell layer (GCL) thickness measurements were collected from normal and early glaucoma cohorts including 25 subjects each. GCc was calculated from GCL thickness data and correlated with DLSs for different stimulus sizes.RESULTS. Correlation coefficients attained with smaller stimulus size were higher compared to larger stimulus sizes in both normal (GI-GII: R 2 ¼ 0.41-0.43, GIII-GV: R 2 ¼ 0.16-0.41) and diseased cohorts (GI-GII: R 2 ¼ 0.33-0.41, GIII-GV: R 2 ¼ 0.19-0.36). Quadratic regression curves for combined GI to V data demonstrated high correlation (R 2 = 0.82-0.90) and differed less than 1 dB of visual sensitivity within the GCc range between cohorts. The established structure-function relationship was compatible with a histologically derived model correlation spanning the range predicted by stimulus sizes GI to GIII.CONCLUSIONS. Stimulus sizes within critical spatial summation area (GI-II) improved structurefunction correlations in the central visual field. The structure-function relationship was identical in both normal and diseased cohort when GI to GV data were combined. Congruency of GI and GII structure-function correlation with those previously derived with GIII from more peripheral locations further suggests that the structure-function relationship is governed by the number of ganglion cell per stimulus area.
White‐on‐white standard automated perimetry (SAP) is widely used in clinical and research settings for assessment of contrast sensitivity using incremental light stimuli across the visual field. It is one of the main functional measures of the effect of disease upon the visual system. SAP has evolved over the last 40 years to become an indispensable tool for comprehensive assessment of visual function. In modern clinical practice, a range of objective measurements of ocular structure, such as optical coherence tomography, have also become invaluable additions to the arsenal of the ophthalmic examination. Although structure‐function correlation is a highly desirable determinant of an unambiguous clinical picture for a patient, in practice, clinicians are often faced with discordance of structural and functional results, which presents them with a challenge. The construction principles behind the development of SAP are used to discuss the interpretation of visual fields, as well as the problem of structure‐function discordance. Through illustrative clinical examples, we provide useful insights to assist clinicians in combining a range of clinical results obtained from SAP and from advanced imaging techniques into a coherent picture that can help direct clinical management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.