The steroidal module of the Athlete Biological Passport (ABP) has been used since 2014 for the longitudinal monitoring of urinary testosterone and its metabolites in order to identify samples suspicious for the use of synthetic forms of endogenous anabolic androgenic steroids (EAAS). Samples identified by the module may then be confirmed by isotope ratio mass spectrometry (IRMS) to establish clearly the exogenous origin of testosterone and/or metabolites in the sample. To examine the detection capability of the steroidal ABP model, testosterone administration studies were performed with various doses and three routes of administrationtransdermal, intramuscular, and subcutaneous with 15 subjects for each route of administration. Urine samples were collected before, during, and after administration and steroid profiles were analyzed using the steroidal ABP module in ADAMS. A subset of samples from each mode of administration was also analyzed by IRMS. The steroidal ABP module was more sensitive to testosterone use than population-based thresholds and with high dose administrations there was very good agreement between the IRMS results and samples flagged by the module. However, with low dose administration the ABP module was unable to identify samples where testosterone use was still detectable by IRMS analysis. The testosterone/epitestosterone (T/E) ratio was the most diagnostic parameter for longitudinal monitoring with the exception of low testosterone excretors for whom the 5α-androstane-3α, 17β-diol/epitestosterone (5αAdiol/E) ratio may provide more sensitivity.
Athletes abuse recombinant human erythropoietin (rhEPO) and erythropoiesis stimulating agents to increase hemoglobin mass and improve performance. To evade detection, athletes have developed sophisticated blood doping regimens, which often include rhEPO micro-dosing. Detection of these methods requires biomarkers with increased sensitivity and a sample matrix that is more amenable to frequent testing in the field. We have developed a method to measure two immature reticulocyte proteins, CD71 and ferrochelatase (FECH), and one total erythrocyte protein, Band 3, in dried blood spots (DBS). This method was tested in response to rhEPO administration after low doses, 40 IU/kg, micro-doses, 900 IU, or saline injection in 20 healthy subjects. During administration of low-dose rhEPO, the mean CD71/Band 3 and FECH/Band 3 ratio increased by 412 ± 197% and 250 ± 44%, respectively. The mean response for the current biomarker, RET%, increased by 195 ± 35%. During administration of rhEPO micro-doses, CD71/Band 3 increased to 127 ± 25% on day 35 and 139 ± 36% on day 39, while no increase was observed in RET%. After rhEPO administration, during the washout phase, mean values decreased to a minimum of 64 ± 4% and 64 ± 11% for CD71/Band 3 and RET%, respectively. However, CD71/Band 3 remained below 75% of base-
Identification and evaluation of long‐term markers is crucial in prolonging the detection window for anabolic steroid abuse in sport. Recently, sulfoconjugated epiandrosterone was identified as a potential long‐term marker for the abuse of certain endogenous anabolic agents, including testosterone, which continues to be widely used as a performance enhancing agent in sport. To evaluate the applicability of epiandrosterone sulfate as a marker for testosterone use, administration studies were conducted with multiple modes of testosterone administration – transdermal, intramuscular, and subcutaneous. A modified sample preparation method was used to collect both glucuronidated and sulfoconjugated analytes of interest. Carbon isotope ratio measurements from the administration studies are presented here. Epiandrosterone was less effective than the conventionally used target compounds for detection of the low dose application (transdermal gel). With intramuscular administration, epiandrosterone was more diagnostic than with transdermal administration, but it did not prolong the detection window more than the conventional target compounds. With subcutaneous administration, the doses administered to the subjects were varied and the effect on the epiandrosterone values was dependent on the magnitude of the dose administered. Epiandrosterone does not appear to be a useful marker in the detection of low dose testosterone administration. It is responsive to higher dose administration, but it does not provide an extension of the detection window relative to conventional target compounds.
Background Immature reticulocytes (IRC) are the first cells to respond to changes in erythropoiesis. For antidoping applications, measurement of IRC may improve detection of blood doping practices. Unfortunately, this small cell population has limited stability in liquid blood samples and is difficult to measure with optimal precision. We developed a method to measure 3 IRC membrane proteins in dried blood spots (DBS) to monitor changes in erythropoiesis. Methods DBS spots were washed with buffers to remove soluble proteins, membrane proteins remaining in the spot were digested with trypsin, and one peptide for each protein was measured by LC-MS/MS. IRC protein concentration was determined using a DBS single point calibrator. Results Intraassay precision for IRC proteins was between 5%–15%. IRC proteins were stable in DBS for 29 days at room temperature. In a longitudinal study of 25 volunteers, the mean intraindividual variation for 3 IRC proteins was 17%, 20%, and 24% from capillary blood DBS. In comparison, the mean longitudinal variation for IRC counts measured on an automated hematology analyzer was 38%. IRC protein concentration from capillary blood DBS correlated well with venous blood DBS protein concentrations. Conclusions Measurement of IRC proteins in DBS samples provides a method to measure changes in erythropoiesis with improved analytical sensitivity, stability, and precision. When combined with the inherent advantages of capillary blood collection in the field, this method may substantially improve the detection of blood doping practices.
The steroidal module of the Athlete Biological Passport (ABP) has been used since 2014 for the longitudinal monitoring of urinary testosterone and its metabolites to identify samples suspicious for the use of synthetic forms of Endogenous Anabolic Androgenic Steroids (EAAS). Multiple recent studies have suggested that monitoring of blood parameters may provide enhanced detectability of exogenous testosterone administration. Transdermal and intramuscular testosterone administration studies were carried out in 15 subjects, and the effect on blood steroidal levels, hematological parameters, and gonadotropins was evaluated. Serum testosterone and dihydrotestosterone levels increased while gonadotropin levels were suppressed after administration. A modest increase in reticulocytes was also observed. The blood parameters that were responsive to the administrations were combined into several linear discriminant models targeting both administration (on) and washout (off) phases. The models were effective in detecting the large dose intramuscular administration but were less successful in the detection of the lower dose transdermal application. The blood profiling models may provide complementary value but do not appear to be substantially more advantageous than longitudinal urinary profiling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.