Previous experimental studies have clearly demonstrated the existence of drifting and stationary electrical spiral waves in cardiac muscle and their involvement in cardiac arrhythmias. Here we present results of a study of reentrant excitation in computer simulations based on a membrane model of the ventricular cell. We have explored in detail the parameter space of the model, using tools derived from previous numerical studies in excitation-dynamics models. We have found appropriate parametric conditions for sustained stable spiral wave dynamics (1 s of activity or approximately 10 rotations) in simulations of an anisotropic (ratio in velocity 4:1) cardiac sheet of 2 cm x 2 cm. Initially, we used a model that reproduced well the characteristics of planar electrical waves exhibited by thin sheets of sheep ventricular epicardial muscle during rapid pacing at a cycle length of 300 ms. Under these conditions, the refractory period was 147 ms; the action potential duration (APD) was 120 ms; the propagation velocity along fibers was 33 cm/s; and the wavelength along fibers was 4.85 cm. Using cross-field stimulation in this model, we obtained a stable self-sustaining spiral wave rotating around an unexcited core of 1.75 mm x 7 mm at a period of 115 ms, which reproduced well the experimental results. Thus the data demonstrate that stable spiral wave activity can occur in small cardiac sheets whose wavelength during planar wave excitation in the longitudinal direction is larger than the size of the sheet. Analysis of the mechanism of this observation demonstrates that, during rotating activity, the core exerts a strong electrotonic influence that effectively abbreviates APD (and thus wavelength) in its immediate surroundings and is responsible for the stabilization and perpetuation of the activity. We conclude that appropriate adjustments in the kinetics of the activation front (i.e., threshold for activation and upstroke velocity of the initiating beat) of currently available models of the cardiac cell allow accurate reproduction of experimentally observed self-sustaining spiral wave activity. As such, the results set the stage for an understanding of functional reentry in terms of ionic mechanisms.
Abstract-Ventricular fibrillation (VF) is the leading cause of sudden cardiac death. Yet, the mechanisms of VF remain elusive. Pixel-by-pixel spectral analysis of optical signals was carried out in video imaging experiments using a potentiometric dye in the Langendorff-perfused guinea pig heart. Dominant frequencies (peak with maximal power) were distributed throughout the ventricles in clearly demarcated domains. The fastest domain (25 to 32 Hz) was always on the anterior left ventricular (LV) wall and was shown to result from persistent rotor activity. Intermittent block and breakage of wavefronts at specific locations in the periphery of such rotors were responsible for the domain organization. Patch-clamping of ventricular myocytes from the LV and the right ventricle (RV) demonstrated an LV-to-RV drop in the amplitude of the outward component of the background rectifier current (I B ). Computer simulations suggested that rotor stability in LV resulted from relatively small rectification of I B (presumably I K1 ), whereas instability, termination, and wavebreaks in RV were a consequence of strong rectification. This study provides new evidence in the isolated guinea pig heart that a persistent high-frequency rotor in the LV maintains VF, and that spatially distributed gradients in I K1 density represent a robust ionic mechanism for rotor stabilization and wavefront fragmentation.
Abbreviation of the action potential duration and/or effective refractory period (ERP) is thought to decrease the cycle length of reentrant arrhythmias. Verapamil, however, paradoxically converts ventricular fibrillation (VF) to ventricular tachycardia (VT), despite reducing the ERP. This mechanism remains unclear. We hypothesize that the size and the dynamics of the core of rotating waves, in addition to the ERP, influence the arrhythmia manifestation (ie, VF or VT). The objectives of this study were (1) to demonstrate functional reentry as a mechanism of VF and VT in the isolated Langendorff-perfused rabbit heart in the absence of an electromechanical uncoupler and (2) to elucidate the mechanism of verapamil-induced conversion of VF to VT. We used high-resolution video imaging with a fluorescent dye, ECG, frequency and 2-dimensional phase analysis, and computer simulations. Activation patterns in 10 hearts were studied during control, verapamil perfusion (2x10(-6) mol/L), and washout. The dominant frequency of VF decreased from 16.2+/-0.7 to 13.5+/-0.6 Hz at 20 minutes of verapamil perfusion (P<0.007). Concomitantly, phase analysis revealed that wavefront fragmentation was reduced, as demonstrated by a 3-fold reduction in the density of phase singularities (PSs) on the ventricular epicardial surface (PS density: control, 1.04+/-0.12 PSs/cm(2); verapamil, 0.32+/-0.06 PSs/cm(2) [P=0.0008]). On washout, the dominant frequency and the PS density increased, and the arrhythmia reverted to VF. The core area of transiently appearing rotors significantly increased during verapamil perfusion (control, 4.5+/-0.6 mm(2); verapamil, 9.2+/-0.5 mm(2) [P=0.0002]). In computer simulations, blockade of slow inward current also caused an increase in the core size. Rotating waves underlie VF and VT in the isolated rabbit heart. Verapamil-induced VF-to-VT conversion is most likely due to a reduction in the frequency of rotors and a decrease in wavefront fragmentation that lessens fibrillatory propagation away from the rotor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.