The 5.98 inch-sized World's first flexible OLED display has been developed and launched mass production on smartphone with extremely light, thin and curved shape, successfully. We have employed ELA-TFT on PI backplane, Face-sealing encapsulation, Laser-assisted glass release and flexible backplate lamination process. These technologies enable panel reliability as well as mass production with inherent flexible display characteristics. For commercializing flexible OLED, technical barriers and challenges on TFT device, panel design and various process technologies including LG Display's recent experience will be presented in this paper.
Background. The application of additive manufacturing (3D printing) has been recently expanded to various medical fields. The new technique named loss of guide wire resistance (LOGR) was developed via 3D printing for the detection of epidural space using a guide wire instead of air or saline used in the loss of resistance (LOR) technique. Methods. The prototype model of epidural space finder consists of a polyactic acid (PLA) or a resin. It was manufactured with 3D printing. Biocompatibility test (eluate and sterility tests) was performed in both products. The advantage of the newly developed device was compared with conventional loss of resistance (LOR) technique in a porcine model. Results. Eluate and sterility tests revealed that the PLA was more biocompatible than the resin. The LOGR technique facilitated rapid access to epidural space compared with the LOR technique (41.64 ± 32.18 vs. 92.28 ± 61.46 seconds, N = 14, p=0.0102, paired sample t-test), without any differences in success rate (87.5%). Conclusion. We conclude that LOGR technique is comparable to LOR technique to access the epidural space, although the advantage of either technique in terms of complications such as dural puncture or epidural hematoma is unknown. We demonstrated the potential benefit of 3D printer for the development of a new medical device for anesthesia.
Epidural fibrosis is a contributing factor to the persistent pain that is associated with failed back surgery syndrome (FBSS) and other pathophysiologies, particularly as it inhibits the passage of regional medications to areas responsible for pain. Therefore, effective mechanical detachment of epidural fibrosis can contribute to pain reduction and improve function in FBSS patients. In this report, we describe the successful treatment of FBSS patients with epidural adhesiolysis using a Fogarty catheter via the transforaminal approach.
Recently, parallel operation of dc-dc converters has been widely used in distributed power systems. In this paper, a control method to achieve parallel operation of three-phase bi-directional isolated interleaved dc-dc converters is discussed for the battery charging and discharging system which consists of the 32 battery charger/dischargers and two three-phase bi-directional isolated interleaved dc-dc converters. In the boost mode, the battery energy is delivered to the grid, whereas the grid energy is transferred to the battery in the buck mode operation. The average current sharing control method is employed to obtain an equal conducting of each phase current in the three-phase dc-dc converter. By using the proposed method, the imbalance factor is gratefully reduced from 8 percent to 1 percent. Two 2.5kW three-phase bi-directional dc-dc converter prototype have been built and the proposed method has been verified through experiments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.