BackgroundSerum prostate-specific antigen (PSA) is widely used in screening tests for prostate cancer. As the low specificity of PSA results in unnecessary and invasive prostate biopsies, we evaluated the clinical significance of various PSAs and PSA density (PSAD) related to peripheral zones in patients with gray zone PSA level (4-10 ng/mL).MethodsA total of 1,300 patients underwent transrectal ultrasonography-guided prostate biopsy from 2014 to 2019. Among them, 545 patients in the gray zone were divided into the prostate cancer diagnosis group and the non-prostate cancer diagnosis group, and PSA, relative extra transitional zone PSA (RETzPSA), estimated post holmium laser enucleation of the prostate PSA (EPHPSA), PSAD, peripheral zone PSA density (PZPSAD) and extra-transitional zone density (ETzD) were compared and analyzed using receiver-operating characteristics (ROC) analysis after 1:1 matching using propensity score.ResultsArea under the ROC curve values of PSA, EPHPSA, RETzPSA, PSA density, ETzD, and PZPSAD were 0.553 (95% CI: 0.495-0.610), 0.611 (95% CI: 0.554-0.666), 0.673 (95% CI: 0.617-0.725), 0.745 (95% CI: 0.693-0.793), 0.731 (95% CI: 0.677-0.780) and 0.677 (95% CI: 0.611-0.719), respectively. PSAD had 67.11% sensitivity, 71.71% specificity, and 70.34% positive predictive rate at 0.18 ng/mL/cc. ETzD had 69.08% sensitivity, 64.47% specificity, and 66.04% positive predictive rate at 0.04 ng/mL/cc. When the cut-off value of PSAD was increased to 0.18 ng/mL/cc, the best results were obtained with an odds ratio of 5.171 (95% CI: 3.171-8.432), followed by ETzD with 4.054 (95% CI: 2.513-6.540).ConclusionsThese results suggested that volume-adjusted parameters (ETzD and PSAD) might be more sensitive and accurate than various PSA in gray zone patients who required prostate biopsy to reduce unnecessary biopsy.
Purpose: This clinical study sought to evaluate the possible clinical effectiveness and practicality of URINO, an innovative, incisionless, and disposable intravaginal device, designed for patients suffering from stress urinary incontinence.Methods: A prospective, multicenter, single-arm clinical trial was carried out, involving women diagnosed with stress urinary incontinence who used a self-inserted, disposable intravaginal pessary device. Comparisons were made between the results of the 20-minute pad-weight gain (PWG) test at baseline and visit 3, where the device was applied. After 1 week of device usage, compliance, satisfaction, the sensation of a foreign body, and adverse events were assessed.Results: Out of 45 participants, 39 completed the trial and expressed satisfaction within the modified intention-to-treat group. The average 20-minute PWG of participants was 17.2±33.6 g at baseline and significantly dropped to 5.3±16.2 g at visit 3 with device application. A total of 87.2% of participants exhibited a reduction ratio of PWG by 50% or more, surpassing the clinical trial success benchmark of 76%. The mean compliance was recorded as 76.6%±26.6%, the average visual analogue scale score for patient satisfaction was 6.4±2.6, and the sensation of a foreign body, measured on a 5-point Likert scale, was 3.1±1.2 after 1 week of device use. No serious adverse events were reported; there was 1 instance of microscopic hematuria and 2 cases of pyuria, all of which recovered.Conclusions: The investigated device demonstrated significant clinical effectiveness and safety for patients with stress urinary incontinence. It was easy to use, showing favorable patient compliance. We propose that these disposable intravaginal pessaries could potentially be an alternative treatment for patients with stress urinary incontinence who are seeking nonsurgical options or are unable to undergo surgery.Trial Registration: The study was registered as a clinical trial (KCT0008369).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.