As a medical center without a pre-existing radiopharmaceutical therapy program, it was a daunting endeavor to implement a 131I metaiodobenzylguanidine (mIBG) high-dose treatment regimen. It took several years of planning with hospital administration, vendors, and Texas Department of Health Radiological Control regulators to establish a viable program. Effective communication between physicians, nursing, nuclear medicine, environmental services, maintenance, and other support staff is essential and paramount for the successful execution and continued sustainability of the mIBG therapy program. Besides providing an effective treatment for patients, an additional goal for the program is to keep radiation exposure As Low As Reasonably Achievable (ALARA) for staff and patient caregivers. As such, start-up presented many training, logistical, and radiation safety challenges. The location of the isolation room and shielding specifications were designed to keep radiation exposure to public access areas to less than 2 microsieverts per hour. Before the first patient was treated the policies and procedures for training, radiation safety, product quality control, and infusion process needed to be developed, tested, and approved by various committees. Furthermore, a similar process was required for developing room set-up, post therapy cleanup, and waste storage procedures. Throughout the maturation process of the program, the departments involved have found that our safety culture has continually improved by the re-enforcement of knowledge and lessons learned, as both the ancillary and treatment staff grew more confident in each other’s ability during more patient treatments are performed. This article describes the process and lessons learned during the time leading up to the startup and early years of the mIBG therapy program.
I-metaiodobenzylguanidine ( 131 I-MIBG) is a theranostic agent useful for treatment of neuroendocrine malignancies. In this case, a child with a Curie score of 21 was administered 17.871 GBq (483 mCi) of 131 I-MIBG. The elimination half-life progressively increased from 23 h to 77 h during the 11 d that the patient was hospitalized for radiation isolation. Six weeks after the posttherapy scan, a survey with an ion-chamber device yielded readings of 0.3 μSv/h (0.03 mR/h) on contact with spinal regions that had shown increased uptake on the scan. A planar image obtained using the 131 I setting and a high-energy collimator did not demonstrate any focal uptake. 123 I-MIBG was administered, and the 24-h scan was of diagnostic quality, without degradation from the remaining 131 I-MIBG. Additional study is needed on whether the Curie score affects elimination of 131 I-MIBG and on whether the period of hospitalized radiation isolation needs to be extended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.