Conservative stems conserve a larger amount of bone, and due to their biomechanical effect, they allow higher compression forces on the lateral column of the femur and reduce stress shielding. Since they conserve metaphyseal bone, short stems allow the use of conventional stems when revision surgery becomes necessary. The authors present the early results of a new bone conserving stem GTS (Biomet). A total of 80 patients (55 men and 25 women) were enroled in this prospective study and received 81 GTS stem (1 bilateral). Their mean age was 64.8 years (range 43-78) at the time of surgery. The mean follow-up was 16 months (range 6-24 month). The clinical assessment was performed by a single surgeon using the Merle d'Aubigné scale; radiographic complications were described. There was one calcar fracture, which required a fixation with a screw. No cases of clinical or radiological loosening were reported. GTS Conservative hip arthroplasty stem has proven to be an excellent implant for femoral hip replacement, with expectations that it may exceed the durability of other types of implants without harming the femoral diaphysis. This may facilitate eventual stem revision and give surgeons the opportunity of using a standard primary implant.
The use of the GTS conservative short stem in patients over 70 years old has shown very good results and low complication rates, comparable to those for patients younger than 70 years.
Objectives:Severe pelvic deficiency presents a difficult problem in hip arthroplasty. Specifically, the goals are to restore the pelvic bone stock, place the acetabular component in the correct anatomical position, and optimize joint stability. Currently, many surgical techniques have been developed for prosthetic revision surgery for acetabular complex defects, but no consensus has been reached on the best treatment. The objective of this study was to review mid-term cases of severe bone defect (Paprosky type III) treated with a bone allograft and ring Bursch-Schneider anti-protrusion cage (BSAC).Methods:A retrospective consecutive series review of the first 23 complex acetabular reconstructions performed between 2006 and 2011 was conducted. The series included the learning curve of the procedure and a minimum 5-year follow-up.Conclusion:Our study confirmed the efficacy of using a frozen morselized allograft combined with a metal ring-type BSAC for acetabular reconstruction. The anatomical location of the center of rotation of the hip must be recovered for long-term success. In massive loosening cases, the anatomical center of rotation can only be restored by bone density reconstruction using a graft protected by a ring to improve the centering of the head. Level of Evidence IV, Case Series.
Introduction: The aim of our work is to review those patients who underwent prosthetic hip revision surgery in our hospital considered to be patients at high risk of dislocation or recurrent dislocation, and who underwent a double mobility cemented cup (CMD). Analyzing the different ways to place these cups and the clinical results and reluxations. Material and methods: The 69 cases comprised 34 men and 35 women with a mean age of 77,39 years. The mean follow-up was 4.7536 years. The type of intervention performed varied according to the cause of the intervention, the acetabular bone stock and the state of the primary cup. In the cases in which there was a good fixation of the primary metalback, we opted to carry out a cementation of the cemented DMC into the existing well-fixed metal acetabular shell, this occurred in 23 cases. In the cases where there was loosening of the primary cup but there was a good bone stock, a CMD was cemented into the bone (21 cases). In the cases where there was a Paprosky type III we cemented a DMC to a Bursch-Schneider reinforcement ring together with the placement of a cancellous bone graft (25 cases). Results: The clinical evaluation at the end of the follow-up, according to the MD Scale, showed the mean value was 16.454 (SD 0.79472), with a survival at the end of the follow-up of 100% of the placed DMC. Conclusion: The use of cemented DMC is a good solution in the replacement of THA, especially in cases of reluxation or risk of dislocation due to personal or technical predisposing factors. The use of these DMC cemented can be directly to the bone, into the existing well-fixed metal Shell, or cemented to a reinforcing ring, depending on the acetabular defect. Evidence Level III; Comparative Case Series.
Background Prosthetic surgery has shown good short-term results with the use of short stems, results comparable with the experience of conventional stems. The aim of this study was to investigate and describe the characteristics and clinical course of patients operated on with the short stem GTS in the medium term. Methods Between November 2010 and September 2014, 152 primary hip prostheses were operated on in 142 patients with a mean follow-up of 95.49 months (range 75–120). We analyzed the intraoperative and postoperative complications and the reviews performed during the follow-up. Results One intraoperative complications occurred; case in which a femoral calcar fracture occurred and a screw was required during the operation. The clinical evaluation at the end of the follow-up, according to the Merle D’Aubigne Scale, showed the mean value was 17.3684 (SD 0,79472), with a survival at the end of the follow-up of 99.3% of the placed GTS stems. Conclusions GTS short stems have shown good results after more than 6 years of follow-up, with comparable results to conventional uncemented stems. Short-stem hip arthroplasty is an advanced way to preserve bone stock while protecting soft tissue
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.