Background: Conventional mapping of focal ventricular arrhythmias relies on unipolar electrogram characteristics and early local activation times. Deep intramural foci are common and associated with high recurrence rates following catheter-based radiofrequency ablation. We assessed the accuracy of unipolar morphological patterns and mapping surface indices to predict the site and depth of ventricular arrhythmogenic focal sources. Methods: An experimental beating-heart model used Langendorff-perfused, healthy swine hearts. A custom 56-pole electrode array catheter was positioned on the left ventricle. A plunge needle was placed perpendicular in the center of the grid to simulate arrhythmic foci at variable depths. Unipolar electrograms and local activation times were generated. Simulation models from 2 human hearts were also included with grids positioned simultaneously on the endocardium-epicardium from multiple left ventricular, septal, and outflow tract sites. Results: A unipolar Q or QS complex lacks specificity for superficial arrhythmic foci, as this morphology pattern occupies a large surface area and is the predominant pattern as intramural depth increases without developing a R component. There is progressive displacement from the arrhythmic focus to the surface exit as intramural focus depth increases. A shorter total activation time over the overlying electrode array, larger surface area within initial 20 ms activation, and a dual surface breakout pattern all indicate a deep focus. Conclusions: Displacement from the focal intramural origin to the exit site on the mapping surface could lead to erroneous lesion delivery strategies. Traditional unipolar electrogram features lack specificity to predict the intramural arrhythmic source; however, novel endocardial-epicardial mapping surface indices can be used to determine the depth of arrhythmic foci.
Cardiac fiber direction is an important factor determining the propagation of electrical activity, as well as the development of mechanical force. In this paper, we imaged the ventricles of several species with special attention to the intraventricular septum to determine the functional consequences of septal fiber organization. First, we identify a dual-layer organization of the fiber orientation in the intraventricular septum of ex-vivo sheep hearts using diffusion tensor imaging at high field MRI. To expand the scope of the results, we investigate the presence of similar fiber organization on five mammalian species (rat, canine, pig, sheep, human) and highlight the continuity of the layer with the moderator band in large mammalian species. We implemented the measured septal fiber fields in 3D electromechanical computer models to assess the impact of the fiber orientation. The downward fibers produced a diamond activation pattern superficially in the RV. Electromechanically, there was very little change in pressure volume loops although the stress distribution was altered. In conclusion, we clarified that the RV septum has a downwardly directed superficial layer in larger mammalian species, which can have modest effects on stress distribution.
Aims Electroanatomical maps using automated conduction velocity (CV) algorithms are now being calculated using two-dimensional (2D) mapping tools. We studied the accuracy of mapping surface 2D CV, compared to the three-dimensional (3D) vectors, and the influence of mapping resolution in non-scarred animal and human heart models. Methods and results Two models were used: a healthy porcine Langendorff model with transmural needle electrodes and a computer stimulation model of the ventricles built from an MRI-segmented, excised human heart. Local activation times (LATs) within the 3D volume of the mesh were used to calculate true 3D CVs (direction and velocity) for different pixel resolutions ranging between 500 μm and 4 mm (3D CVs). CV was also calculated for endocardial surface-only LATs (2D CV). In the experimental model, surface (2D) CV was faster on the epicardium (0.509 m/s) compared to the endocardium (0.262 m/s). In stimulation models, 2D CV significantly exceeded 3D CVs across all mapping resolutions and increased as resolution decreased. Three-dimensional and 2D left ventricle CV at 500 μm resolution increased from 429.2 ± 189.3 to 527.7 ± 253.8 mm/s (P < 0.01), respectively, with modest correlation (R = 0.64). Decreasing the resolution to 4 mm significantly increased 2D CV and weakened the correlation (R = 0.46). The majority of CV vectors were not parallel (<30°) to the mapping surface providing a potential mechanistic explanation for erroneous LAT-based CV over-estimation. Conclusion Ventricular CV is overestimated when using 2D LAT-based CV calculation of the mapping surface and significantly compounded by mapping resolution. Three-dimensional electric field-based approaches are needed in mapping true CV on mapping surfaces.
The implementation of numerical methods to solve and study equations for cardiac wave propagation in realistic geometries is very costly, in terms of computational resources. The aim of this work is to show the improvement that can be obtained with Chebyshev polynomials-based methods over the classical finite difference schemes to obtain numerical solutions of cardiac models. To this end, we present a Chebyshev multidomain (CMD) Pseudospectral method to solve a simple two variable cardiac models on three-dimensional anisotropic media and we show the usefulness of the method over the traditional finite differences scheme widely used in the literature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.