Context There are no scientific reports unambiguously describing the efficacy of alternating magnetic field therapy in patients after anterior cruciate ligament (ACL) reconstruction in the early postoperative period. Objective This study aims to evaluate the efficacy of using an alternating magnetic field in the resorption of postoperative joint effusion in patients after ACL reconstruction. Study design A randomized, double-blind placebo-controlled study. Setting Inpatients. Participants Forty patients were enrolled in the trial. However, the final study group consisted of 38 patients (28 men and 10 women) after ACL reconstruction who were randomly divided into an experimental group (19 patients) and a control group (19 patients). Intervention Each group received magnetic field therapy in the postoperative period, but only 1 apparatus emitted a magnetic field (the experimental group). Patients used the apparatus every day for 30 minutes for the next 11 days. The parameters in both devices were the same—3 mT and 10 Hz. Main outcome measures The measurement of the knee circumference and range of motion were made. The knee circumference measurement was performed before magnetic field therapy began and for 11 days after magnetic field treatment. The active knee range of motion was evaluated before and after magnetic field therapy was completed. Results There were no statistically significant differences between the groups in the reduction of post-operative joint effusion or knee joint function. Conclusion In patients after ACL reconstruction , in whom an alternating magnetic field was used to treat postoperative joint effusion, there were no beneficial effects on the analyzed variables compared to the control group.
Background There are no scientific reports clearly describing the effectiveness of the High Tone Power Therapy in patients after ACL reconstruction. This caused that in own research an attempt was made to present the possibilities of using the selected method of electrical stimulation in the treatment of an orthopaedic patient. The aim was to assess the effectiveness of electro stimulation of the quadriceps muscle in patients after ACL reconstruction, with the use of High Tone Power Therapy. Methods In randomized controlled trial took part thirty-five men, aged 21–50, after ACL reconstruction. The tests were carried prior to and 6 months following the ACL reconstruction. After the surgery, the patients were randomly divided into experimental group (17 patients) with the High Tone Power Therapy in rehabilitation and control group (18 patients) without the High Tone Power Therapy. Patients were subjected to 6-month rehabilitation. Research tools included the measurement of muscle strength torque, ROM, knee and thigh circumference measurements, the Lysholm and the VAS scale. Results After applying HiToP, the analysis showed a statistically significant improvement of muscle torque (p = 0.041, Es = 3.71), knee circumference (p = 0.039, Es = 1.65), thigh circumference (p = 0.049, Es = 1.26), knee extension (p < 0.001, Es = 2.20) in Experimental group compared to the control group. Only the results of the VAS scale did not differ statistically significantly both within a given group and between groups. Conclusions The results confirm the hypothesis that the use of HiToP in patients after ACLr have a beneficial effect on muscle strength, reduction of joint effusion, muscle mass gain and joint function. The assumption that HiToP significantly reduces pain levels is not supported - the results in both groups are statistically insignificant. Trial registration The research project was retrospectively registered in the Australian New Zealand Clinical Trials Registry (ANZCTR). Date of first registration 11.10.2016. Registration number: ACTRN12616001416482.
Background The aim of the study was the assessment of the early impact of the selected kinesiotaping technique on the static stability of the knee joint in patients with ACL rupture on the basis of stabilographic parameters. Methods Sixty-two patients with a complete ACL rupture (32 patients in experimental group and 30 patients in placebo group) took part in the randomized single-blind, placebo-controlled trial. The ligament technique of KT was taken into consideration. Application of a KT tape only on the injured knee was to stabilize the knee joint. Experimental group had application of KT on the injured knee and the placebo group had a KT placebo application (with no tension on KT). Intervention and stabilographic test in both groups was the same. Research tools included measurements of static stabilographic parameters on stabilometric platform CQStab2P®. Outcome measures were assessed before intervention and after KT application. The analysis included evaluation of outcome variables – total path length, (SP), statokinesiogram path length in the XY axes (SPML, SPAP), and mean velocities in the XY axes (MV, MVML, MVAP). Results The results show a statistically significant shortening of the SP, SPAP and SPML variables only in experimental group. In the placebo group the results were not significant. The analysis also showed a significant improvement in all analyzed variables in the experimental group compared to the healthy side. In the placebo group, the results did not improve significantly after KT application compared to the healthy side. Conclusions Application o f KT in patients after ACL rupture shortened the total path length and improved the value of parameters in the frontal and sagittal planes in experimental group, which may suggest the potentially greater improvement in these parameters. By improving the values of the analyzed variables, the KT application is able to compensate for the loss of static stability of the knee. Trial Registration This study was registered retrospectively in the Australian New Zealand Clinical Trials Registry (ANZCTR). Registration number: ACTRN12616001407482.
BackgroundA relatively new method of electrotherapy is High Tone Power Therapy. It directly affects cell metabolism, improving metabolic processes in tissues, and pain relief. It can also be used to obtain stimulating effects of the current, in this case also for electro stimulation of the quadriceps. The aim was to assess the effectiveness of electro stimulation of the quadriceps muscle in patients after ACL reconstruction, with the use of High Tone Power Therapy.MethodsIn pre post treatment randomized controlled trial took part thirty-five patients after anterior cruciate ligament reconstruction. The tests were carried prior to and 6 months following the ACL reconstruction. After the surgery, the patients were randomly divided into two research groups – experimental group (17 patients) had the High Tone Power Therapy included in rehabilitation, while the control group (18 patients) was without the High Tone Power Therapy. All patients were subjected to 6-month rehabilitation. Research tools included the measurement of muscle strength torque, ROM, knee and thigh circumference measurements, the Lysholm and the VAS scale ResultsThe analysis showed that there were no statistically significant differences in the measurement of maximum muscle torque of knee extensors between groups and measurements. The analysis did not show any statistically significant differences in other analyzed variables.ConclusionsHigh Tone Power Therapy used in the rehabilitation of patients after ACL reconstruction does not significantly affect the strength of the quadriceps muscle and the function of the knee joint.Trail Registration This study was registered retrospectively in the Australian New Zealand Clinical Trials Registry (ANZCTR). Registration number: ACTRN12616001416482.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.