Background: For almost 30 years, bone-anchored prostheses have offered an alternative solution to prosthetic sockets by attaching the artificial limb directly to the femoral residuum by means of an osseointegration implant. Osseointegration implant surgery was introduced in our center in 2009. The aim of the present study is to report on safety, prosthesis-wearing time, and health-related quality-of-life (HRQoL) for patients with femoral bone-anchored prostheses during a 5-year follow-up period. Methods: All patients who underwent implantation of a press-fit osseointegration implant between May 2009 and November 2013 were eligible for the present study. Implantation was performed in 2 stages. Adverse events included infectious complications (grade 1 to 4), aseptic loosening, breakage, stoma-redundant tissue, and stoma hypergranulation. Prosthesis-wearing time and HRQoL were measured with the Questionnaire for Persons with a Transfemoral Amputation (Q-TFA) prosthetic use score and global score, respectively. Results: Thirty-nine of 42 eligible patients were included. Thirty patients (77%) presented with some kind of infection (156 events in total), with 148 (95%) events being classified as grade 1 or 2 and 8 events (5%) being classified as grade 3; the latter 8 events occurred in 4 patients. There were no instances of septic loosening. The intramedullary stem of the osseointegration implant broke in 2 patients. In total, soft-tissue refashioning had to be done 30 times in 14 patients. The Q-TFA median prosthetic use and global scores improved significantly from 71 to 100 and from 33 to 75, respectively (p < 0.001). Conclusions: Despite the adverse events, patient prosthetic use and HRQoL improved significantly. Grade-1 and 2 infections were frequent but could mostly be treated with nonoperative measures. Most infections seemed to occur in the first 2 years and did not lead to deep infections. Two broken intramedullary stems were revised successfully. Current developments focus on reduction of infectious complications and prevention of osseointegration implant breakage. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Background Septic loosening and stem breakage due to metal fatigue is a rare but well-known cause of orthopaedic implant failure. This may also affect the components of the osseointegrated implant system for individuals with transfemoral amputation who subsequently undergo revision. Identifying risk factors is important to minimize the frequency of revision surgery after implant breakage. Questions/purposes (1) What proportion of patients who received an osseointegrated implant after transfemoral amputation underwent revision surgery, and what were the causes of those revisions? (2) What factors were associated with revision surgery when stratified by the location of the mechanical failure and (septic) loosening (intramedullary stem versus dual cone adapter)? Methods Between May 2009 and July 2015, we treated 72 patients with an osseointegrated implant. Inclusion criteria were a minimum follow-up of 5-years and a standard pressfit cobalt-chromium-molybdenum (CoCrMb) transfemoral osseointegrated implant. Based on that, 83% (60 of 72) of patients were eligible; a further 3% (2 of 60) were excluded because of no received informed consent (n = 1) and loss to follow-up (n = 1). Eventually, we included 81% (58 of 72) of patients for analysis in this retrospective, comparative study. We compared patient characteristics (gender, age, and BMI), implant details (diameter of the intramedullary stem, length of the dual cone, and implant survival time), and event characteristics (infectious complications and distal bone resorption). The data were retrieved from our electronic patient file and from our cloud-based database and analyzed by individuals not involved in patient care. Failures were categorized as: (1) mechanical failures, defined as breakage of the intramedullary stem or dual-cone adapter, or (2) (septic) loosening of the osseointegrated implant. Results Thirty-four percent (20 of 58) of patients had revision surgery. In 12% (7 of 58) of patients, the reason for revision was due to intramedullary stem failures (six One of the authors (HvdM) certifies receipt of personal payments or benefits, during the study period, in an amount of USD 10,000 to USD 100,000 from OTN Implants. All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request. Clinical Orthopaedics and Related Research® neither advocates nor endorses the use of any treatment, drug, or device. Readers are encouraged to always seek additional information, including FDA approval status, of any drug or device before clinical use. Ethical approval for this study was obtained from the Radboud University Medical Center, Nijmegen, the Netherlands (registration number 2018-4962).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.