In this biomechanical study, there was no mechanical difference in the overall properties between a doubled and tripled tendon graft. Significant cyclic elongation occurred in the third limb of the tripled tendon in comparison with the doubled portioned. Further work is needed to determine whether these mechanical findings translate to clinical practice. Caution should be used when tripling hamstring grafts. In particular, tripling small grafts provides no biomechanical advantage immediately and possibly long term, thus potentially increasing the risk of failure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.