The primary focus of this paper is to study the film cooling performance for a row of cylindrical holes each supplemented with two symmetrical anti vortex holes which branch out from the main holes. The anti-vortex design was originally developed at NASA-Glenn Research Center by Dr. James Heidmann, co-author of this paper. This “anti-vortex” design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film cooling holes. The geometry and orientation of the anti vortex holes greatly affect the cooling performance downstream, which is thoroughly investigated. By performing experiments at a single mainstream Reynolds number of 9683 based on the free stream velocity and film hole diameter at four different coolant-to-mainstream blowing ratio of 0.5, 1, 1.5, 2 and using the transient IR thermography technique, detailed film cooling effectiveness and heat transfer coefficients are obtained simultaneously from a single test. When the anti vortex holes are nearer to the primary film cooling holes and are developing from the base of the primary holes, better film cooling is accomplished as compared to other anti vortex hole orientations. When the anti vortex holes are laid back in the upstream region, film cooling diminishes considerably. Although an enhancement in heat transfer coefficient is seen in cases with high film cooling effectiveness, the overall heat flux ratio as compared to standard cylindrical holes is much lower. Thus cases with anti vortex holes placed near the main holes certainly show promising results.
A conjugate heat transfer solver has been developed and applied to a realistic film-cooled turbine vane for a variety of blade materials. The solver used for the fluid convection part of the problem is the Glenn-HT general multiblock heat transfer code. The solid conduction module is based on the Boundary Element Method (BEM), and is coupled directly to the flow solver. A chief advantage of the BEM method is that no volumetric grid is required inside the solid — only the surface grid is needed. Since a surface grid is readily available from the fluid side of the problem, no additional gridding is required. This eliminates one of the most time consuming elements of the computation for complex geometries. Two conjugate solution examples are presented — a high thermal conductivity Inconel nickel-based alloy vane case and a low thermal conductivity silicon nitride ceramic vane case. The solutions from the conjugate analyses are compared with an adiabatic wall convection solution. It is found that the conjugate heat transfer cases generally have a lower outer wall temperature due to thermal conduction from the outer wall to the plenum. However, some locations of increased temperature are seen in the higher thermal conductivity Inconel vane case. This is a result of the fact that film cooling is a two-temperature problem, which causes the direction of heat flux at the wall to change over the outer surface. Three-dimensional heat conduction in the solid allows for conduction heat transfer along the vane wall in addition to conduction from outer to inner wall. These effects indicate that the conjugate heat transfer in a complicated geometry such as a film-cooled vane is not governed by simple one-dimensional conduction from the vane surface to the plenum surface, especially when the effects of coolant injection are included.
A novel turbine film cooling hole shape has been conceived and designed at NASA Glenn Research Center. This “anti-vortex” design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film cooling holes. This vorticity typically entrains hot freestream gas and is associated with jet separation from the turbine blade surface. The anti-vortex film cooling hole concept has been modeled computationally for a single row of 30 degree angled holes on a flat surface using the 3D Navier-Stokes solver Glenn-HT. A blowing ratio of 1.0 and density ratios of 1.05 and 2.0 are studied. Both film effectiveness and heat transfer coefficient values are computed and compared to standard round hole cases for the same blowing rates. A net heat flux reduction is also determined using both the film effectiveness and heat transfer coefficient values to ascertain the overall effectiveness of the concept. An improvement in film effectiveness of about 0.2 and in net heat flux reduction of about 0.2 is demonstrated for the anti-vortex concept compared to the standard round hole for both blowing ratios. Detailed flow visualization shows that as expected, the design counteracts the detrimental vorticity of the round hole flow, allowing it to remain attached to the surface.
A three-dimensional Navier-Stokes simulation has been performed for a realistic film-cooled turbine vane using the LeRC-HT code. The simulation includes the flow regions inside the coolant plena and film cooling holes in addition to the external flow. The vane is the subject of an upcoming NASA Lewis Research Center experiment and has both circular cross-section and shaped film cooling holes. This complex geometry is modeled using a multi-block grid which accurately discretizes the actual vane geometry including shaped holes. The simulation matches operating conditions for the planned experiment and assumes periodicity in the spanwise direction on the scale of one pitch of the film cooling hole pattern. Two computations were performed for different isothermal wall temperatures, allowing independent determination of heat transfer coefficients and film effectiveness values. The results indicate separate localized regions of high heat flux in the showerhead region due to low film effectiveness and high heat transfer coefficient values, while the shaped holes provide a reduction in heat flux through both parameters. Hole exit data indicate rather simple skewed profiles for the round holes, but complex profiles for the shaped holes with mass fluxes skewed strongly toward their leading edges.
A novel turbine film-cooling hole shape has been conceived and designed at NASA Glenn Research Center. This "antivortex" design is unique in that it requires only easily machinable round holes, unlike shaped film-cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film-cooling holes. This vorticity typically entrains hot freestream gas and is associated with jet separation from the turbine blade surface. The antivortex film-cooling hole concept has been modeled computationally for a single row of 30 deg angled holes on a flat surface using the 3D Navier-Stokes solver GLENN-HT. A blowing ratio of 1.0 and density ratios of 1.05 and 2.0 are studied. Both film effectiveness and heat transfer coefficient values are computed and compared to standard round hole cases for the same blowing rates. A net heat flux reduction is also determined using both the film effectiveness and heat transfer coefficient values to ascertain the overall effectiveness of the concept. An improvement in film effectiveness of about 0.2 and in net heat flux reduction of about 0.2 is demonstrated for the antivortex concept compared to the standard round hole for both blowing ratios. Detailed flow visualization shows that as expected, the design counteracts the detrimental vorticity of the round hole flow, allowing it to remain attached to the surface.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.