Due to the rapidly evolving nature of this outbreak, and in the interests of rapid dissemination of reliable, actionable information, this paper went through expedited peer review. Additionally, information should be considered current only at the time of publication and may evolve as the science develops.
Background Amylase and lipase, pancreatic biomarkers, are measured in acute pancreatitis diagnosis. Since amylase testing does not add diagnostic value, lipase testing alone is recommended. Despite new recommendations, many physicians and staff continue to test both amylase and lipase. Objective To reduce unnecessary diagnostic testing in acute pancreatitis. Methods The pre-checked amylase test within the Emergency Department's Computerised Provider Order Entry (CPOE) abdominal pain order set was changed to an un-checked state but kept as an option to order with a single click. Amylase testing, lipase testing and cost were measured for one year pre-and post-intervention. Results Simple de-selection intervention reduced redundant amylase testing from 71% to 9%, resulting in a percent of decrease of 87% and an annualised saving of approximately $719,000 in charges. Conclusion CPOE de-selection is an effective tool to reduce non-value added activity and reduce cost while maintaining quality patient care and physician choice.
IntroductionOver 40 000 CT scans are performed in our emergency department (ED) annually and utilisation is over 80% capacity. Improving medical appropriateness of CT scans may reduce total number of scans, time, cost and radiation exposure.MethodsLean Six Sigma methodology was used to improve the process. A National Emergency X-Radiography Utilisation Study (NEXUS)-based PowerForm was implemented in the electronic health record and providers were educated on the criteria.ResultsThe rate of potentially medically inappropriate CT C-spine scans decreased from 45% (19/42) to 22% (90/403) (two-proportion test, p=0.002). After the intervention, there was no longer a difference between midlevel providers and physicians in the rate of medically inappropriate orders (19% vs 22%) (two-proportion test, p=0.850) compared with that before the intervention (56% vs 31%) (two-proportion test, p<0.01). Overall rates of CT C-spine scans ordered decreased from 69.3 to 62.6/week (t-test, p=0.019).ConclusionA validated clinical decision-making tool implemented into the medical record can improve quality of care. This study lays a foundation for other imaging studies with validated support tools with similar potential improvements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.