The ability of 20-50 nm nanoparticles to target and modulate the biology of specific types of cells will enable major advancements in cellular imaging and therapy in cancer and atherosclerosis. A key challenge is to load an extremely high degree of targeting, imaging, and therapeutic functionality into small, yet stable particles. Herein we report ~30 nm stable uniformly sized near-infrared (NIR) active, superparamagnetic nanoclusters formed by kinetically controlled self-assembly of goldcoated iron oxide nanoparticles. The controlled assembly of nanocomposite particles into clusters with small primary particle spacings produces collective responses of the electrons that shift the absorbance into the NIR region. The nanoclusters of ~70 iron oxide primary particles with thin gold coatings display intense NIR (700-850 nm) absorbance with a cross section of ~10 −14 m 2 . Because of the thin gold shells with an average thickness of only 2 nm, the r 2 spin-spin magnetic relaxivity is 219 mM −1 s −1 , an order of magnitude larger than observed for typical iron oxide particles with thicker gold shells. Despite only 12% by weight polymeric stabilizer, the particle size and NIR absorbance change very little in deionized water over 8 months. High uptake of the nanoclusters by macrophages is facilitated by the dextran coating, producing intense NIR contrast in dark field and hyperspectral microscopy, both in cell culture and an in vivo rabbit model of atherosclerosis. Small nanoclusters with optical, magnetic, and therapeutic functionality, designed by assembly of *Address correspondence to: kpj@che.utexas.edu, FELDMANM@uthscsa.edu. Supporting Information Available: Reproducibility in nanorose size distribution; porosity of dextran in the shells about the iron oxide particle; estimation of number of particles per nanocluster; average optical density spectra in macrophages labeled with nanorose by hyperspectral microscopy; and laser vaporization of macrophages in vitro. This material is available free of charge via the Internet at http://pubs.acs.org. NIH Public AccessAuthor Manuscript ACS Nano. Author manuscript; available in PMC 2010 September 22. NIH-PA Author ManuscriptNIH-PA Author Manuscript NIH-PA Author Manuscript nanoparticle building blocks, offer broad opportunities for targeted cellular imaging, therapy, and combined imaging and therapy. Keywordsgold; iron oxide; nanocluster; near-infrared; macrophage targeted imaging; MRI; atherosclerosis; cancer Clinical imaging and/or therapy with multifunctional nanoparticles that target specific types of cells has the potential to transform health care in cancer, atherosclerosis, and other diseases. When the nanoparticle diameters are reduced to 20-50 nm, the biological pathways in targeted cells can undergo profound changes. [1][2][3][4][5] Small nanoparticles, the size of small viruses, permeate barriers more rapidly including cell membranes and leaky vasculature in cancers. The efficacy of vaccines may be enhanced with ultrasmall 20 nm nanoparticles that can dif...
The conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [alpha(t)]. We have recently proposed solutions to the problems of both time-varying G(P) and time-varying alpha, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine G(P) and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice (n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error (P < 0.03) (-2.49 +/- 15.33 microl error) compared with those same parameters calculated by SV calibrated conductance (35.89 +/- 73.22 microl error) and by cuvette calibrated conductance (-7.53 +/- 16.23 microl ES and -29.10 +/- 31.53 microl ED error). To utilize the admittance approach, myocardial permittivity (epsilon(m)) and conductivity (sigma(m)) were calculated in additional mice (n = 7), and those results are used in this calculation. In aortic banded mice (n = 6), increased myocardial permittivity was measured (11,844 +/- 2,700 control, 21,267 +/- 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 +/- 13.06 microl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 +/- 1.4 to 12.5 +/- 6.6 mmHg/microl Wei's equation (P < 0.05), 3.3 +/- 1.2 to 8.8 +/- 5.1 mmHg/microl using Baan's equation (P = not significant)]. New theory and method for instantaneous G(P) removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic G(P)) and Wei's equation (dynamic alpha) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.