We recorded outer retinal dysfunction without detectable abnormalities of the corresponding retinal layers in MS patients, not ascribable to retrograde degeneration following ON. The findings complement a growing body of literature reporting primary retinal abnormalities distal to the ganglion cell-inner plexiform layer complex in MS patients, with our data suggesting that this may be a more widespread phenomenon than previously thought. ERG may be of more utility in detecting retinal dysfunction in MS patients than MF-ERG. Analysis of peak times, rather than response amplitudes, is recommended.
BackgroundIcare PRO (ICP) is a new Rebound tonometer that is able to measure intraocular pressure (IOP) in both sitting and reclining positions. In this study, the gold standard Goldmann tonometer (GAT) was compared to ICP and Tono-Pen AVIA (TPA). Hypothesis was that repeatability of GAT is superior to ICP and TPA.Methods36 eyes of 36 healthy caucasian individuals, 13 male and 26 females, 17 right and 19 left eyes have been included in this prospective, randomized, cross-sectional study. The study was conducted at a single site (Dept. of Ophthalmology, UniversityHospital Zurich, Switzerland). Primary outcome measures were Intraclass correlation coefficients (ICC) and coefficients of variation (COV) and test-retest repeatability as visualized by Bland-Altman analysis. Secondary outcome measures were IOP in sitting (GAT, ICP and TPA) and in reclining (ICP and TPA) position.ResultsMean IOP measured by GAT was 14.9±3.5 mmHg. Mean IOP measured by ICP was 15.6±3.1 mmHg (with TPA 14.8±2.7 mmHg) in sitting and 16.5±3.5 mmHg (with TPA 17.0±3.0 mmHg) in reclining positions. COVs ranged from 2.9% (GAT) to 6.9% (ICP reclining) and ICCs from 0.819 (ICP reclining) to 0.972 (GAT).ConclusionsRepeatability is good with all three devices. GAT has higher repeatability compared to the two tested hand-held devices with lowest COVs and highest ICCs. IOP was higher in the reclining compared to the sitting position.Trial registrationThe study was registered to the Clinical Trials Register of the US National Institute of Health, NCT01325324.
This is the first report to implicate CRB1 as the underlying cause of FFR. This phenotype forms the mildest end of the spectrum of CRB1-related diseases.
BackgroundCataract surgery combined with excimer laser trabeculotomy (phaco-ELT) can reduce intraocular pressure (IOP). The aim of this study was to evaluate the effect of phaco-ELT on IOP in patients as a function of preoperative IOP.MethodsPatients with open-angle glacuoma or ocular hypertension who received phaco-ELT between 01/2008 and 10/2009 were included. Patients were assigned based on preoperative IOP either to the study group (≤21 mmHg) or control group (>21 mmHg) in this IRB-approved, prospective, consecutive case series. Visual Acuity, IOP, and number of anti-glaucoma drugs (AGD) were recorded at baseline and 12 months after phaco-ELT. Any postoperative complications were also recorded.Results64 eyes of 64 patients (76.5 ± 9.4 years) were included. Baseline IOP was 19.8 ± 5.3 mmHg (AGD 2.4 ± 1.1) for all eyes, 16.5 ± 2.9 mmHg (AGD 2.5 ± 1.0) for the study group, and 25.8 ± 2.9 mmHg (AGD 2.2 ± 1.4) for the control group. Across the two groups, IOP was reduced by 4.5 ± 5.9 mmHg (-23.0%, p < 0.001) and AGD by 0.9 ± 1.5 (-38.9%, p < 0.001). For the study group IOP was reduced by 1.9 ± 4.4 mmHg (-11. 5 %, p = 0.012) and AGD by 1.1 ± 1.4 (-42.9%, p < 0.001), and for the control group by 9.5 ± 5.4 mmHg (-36.6%, p < 0.001) and AGD by 0.7 ± 1.6 (-29.5%, p = 0.085). There were no serious postoperative complications such as endophthalmitis, significant hyphema, or a severe fibrinous reaction of the anterior chamber.ConclusionsIOP remained significantly reduced from baseline 12 months after phaco-ELT regardless of preoperative IOP levels, with no major complications. The IOP reduction remained constant over the entire follow-up. Hence, phaco-ELT can be considered in glaucoma and ocular hypertensive patients whenever cataract surgery is performed, in order to further reduce IOP or to reduce the requirement for IOP-reducing medications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.