The current literature suggests that the optimal range of radial artery for maximum performance (maturation and primary patency) of RCAVF is at least 2 mm (level 2, grade a). The cephalic vein diameter of at least 2 mm (non-augmented) can result in best maturation and primary patency outcomes (level 2, grade a) and threshold below 1.5 mm is not advocated (level 2, grade b).
The CEUS with its dynamic nature and longer scanning window demonstrated to be a highly sensitive modality for endoleak detection in comparison to CTA in delayed endoleaks type II.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.