Background How significant asymmetries in otolith organ function in the presence of symmetrical and asymmetrical semicircular canal function influence skull vibration-induced nystagmus testing (SVINT) has not been well described. Purpose The aim of the study is to examine the agreement between SVINT and caloric testing, ocular vestibular-evoked myogenic potentials (oVEMP), and cervical vestibular-evoked myogenic potentials (cVEMP) for detecting asymmetric vestibular function. Research Design This is a retrospective study of patients presenting with the chief complaint of vertigo, dizziness, or imbalance. Study Sample A total of 812 patients were studied with a median age at testing of 59 years (interquartile range 46–70; range 18–93) and included 475 (59%) women. Intervention Either the monothermal warm caloric test or alternate binaural bithermal caloric test, oVEMP, and cVEMP tests were administered to all patients. All patients underwent the SVINT prior to vestibular laboratory testing. Data Collection and Analysis Agreement between tests categorized as normal versus abnormal was summarized using percent concordance (PC). Sensitivity and specificity values were calculated for SVINT compared with other tests of vestibular function. Results There was higher agreement between ipsilateral and contralateral SVINT with the caloric test (PC = 80% and 81%, respectively) compared with oVEMP (PC = 63% and 64%, respectively) and cVEMP (PC = 76% and 78%, respectively). Ipsilateral and contralateral SVINT showed higher sensitivity for the caloric test (sensitivity = 47% and 36%, respectively) compared with oVEMP (sensitivity = 26% and 21%, respectively), or cVEMP (sensitivity = 33% vs. 27%, respectively). Specificity of SVINT was high (>80%) for all assessments of vestibular function. Conclusion The presence of SVIN is a useful indicator of the asymmetry of vestibular function between the two ears when making judgments about semicircular canal asymmetry but is less sensitive to asymmetries in otolith organ function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.